हिंदी Call90310 74624
Home›Sanitary and pipes›Plumbing›Solvents and tapes
Plumbing · joining

Solvent cement and Teflon tape: which tin goes on which pipe, and how to use it

The short answer

Solvent cement is not glue. It softens the pipe and the socket so they fuse into one piece. That is why the tin must match the pipe: a PVC tin on CPVC pipe, or the other way, leaves a joint that holds for months and then fails.

UPVC and SWR take PVC solvent (we keep Pipefix PVC 101 and Hold, 100 ml). CPVC takes CPVC solvent only (Truzo, 100 ml). Threaded joints take Teflon tape (4 m roll), never solvent.

1–2 min
Hold the joint stillPrince's figure for CPVC. Astral's Truzo sheet says 30 seconds; we use the longer.
24 h
Before the pressure testPrince, CPVC. Truzo's minimum is 1 h on a cold line, 6 h on a hot one.
Never
Solvent on a threadThreads take Teflon tape. Solvent goes only on sockets.
One tin for each pipe
UPVC · cold waterPVCsolventCPVC · hot waterCPVCsolventSWR · drains (solvent fit)PVCsolventThreaded joint: Teflon tape, no solvent
Schematic. Blue is cold UPVC, red hot CPVC, grey SWR. CPVC solvent (yellow tin) is for CPVC only. Threads, bottom, use tape.
Which tin

Pipe, tin, hold and wait: one table

Check it before you buy. The tin itself prints its own cure time; if it says longer than this table, the tin wins.

PipeJoined withHold stillWait before water
UPVC cold supplyEasyfit, AshirvadPVC solvent: Pipefix PVC 101 or Hold, 100 ml1 to 2 minutes (the safe figure)Read the tin. Usual practice: leave 24 hours before the pressure test
CPVC hot and coldgeyser lineCPVC solvent: Truzo, 100 ml. Yellow1 to 2 minutes (Prince); Truzo says 30 seconds24 hours before the pressure test (Prince); Truzo minimum 1 h cold, 6 h hot
SWR, solvent fitplain partsPVC solvent1 to 2 minutesSame as UPVC
Threaded jointMTA, FTA, tank nipple, GITeflon tape, 4 m rollnonenone; tighten and test

CPVC and UPVC never meet by solvent; they meet through a threaded adapter. Which pipe for which job: CPVC vs UPVC vs PVC vs GI. Hot line: geyser line pipe.

Making the joint

Six steps for every solvent joint

The full eight steps for CPVC, with the pressure test, are on how to join CPVC pipe. The same cut, chamfer, brush and wait apply to UPVC and SWR.

Cut square, chamfer, deburrA square cut, a small bevel on the outer edge, rough edges scraped. A square edge scrapes the cement off as it goes in.
Dry-fit and markPush the pipe in without cement and draw the full socket depth on the pipe with a pen.
Clean and dryWipe pipe and socket with a dry cloth. Water, dust and oil from hands stop the fusing. Not in rain.
Brush the cementUse the brush in the tin, not a finger. Brush at least half the pipe's width. A full coat on the pipe, a lighter one inside the socket.
Push, turn, holdOne straight push to the pen mark with a quarter turn, no hammer. Hold still for 1 to 2 minutes or the socket pushes the pipe back.
Wipe and waitWipe the bead of cement off. Leave it, then test with water, not air.
What happens inside the joint
pipesocket of the fitting cement softens both, they fuse chamfered end pen mark = full depth
Drawn thicker than real. A fused joint cannot be opened and redone: a bad one is cut out.
Teflon tape

Teflon (PTFE) tape: for threads only

It seals a thread where a part screws in: MTA or FTA to a tap, valve, pump or tank, and GI joints.

Do

  • Wrap in the direction the thread tightens (clockwise, looking at the end of the thread), so tightening does not unwind it.
  • A few turns (usual practice: 3 to 5), pulled snug into the grooves.
  • Tighten by hand, then a little more with the tool. Do not over-tighten (Prince).

Do not

  • No tape on a solvent socket.
  • No tape on the tank nipple's washer face: the washer seals there.
  • No solvent on a thread, and no tape where a solvent joint is wanted.

When the thread is old or damaged, thread sealant paste is the alternative; ask us for it. Product page: Teflon tape.

Mistakes

Five reasons a new joint leaks

Wrong tin

PVC solvent on a CPVC hot line fails after months, behind the tile. Match the tin to the pipe.

Wet or dusty surfaces

Do not join in rain or on a dusty floor. Wipe the pipe and socket dry.

Finger instead of brush

A brush spreads an even film. Fingers leave dry patches and oil.

A thick, old tin

Cement that has gone stringy will not fuse. Truzo keeps 18 months from manufacture; check the date and keep the cap tight.

Testing too early

A joint pressed before it cures weeps. Wait the time in the table.

A joint that already drips: water dripping from a pipe joint.

Our shelf

On the rack at Rewa Road

Anything not listed we order; ask on WhatsApp for the time. Prices on the pipe rate board.

Questions people ask us

Short answers

Can I use PVC solvent on CPVC pipe?

No. CPVC needs CPVC solvent, which is made for its material and hot-water duty. PVC solvent on a geyser line is the classic cause of a joint that fails after months.

Can one tin do UPVC and CPVC?

No. Buy a PVC tin for the cold line and a CPVC tin for the hot line, and keep them apart.

Can I join UPVC to CPVC with solvent?

No. Join them through a threaded adapter, with Teflon tape on the thread.

How long before I can run water?

Read the tin first. For CPVC, Prince says 24 hours before the pressure test; Truzo's minimum is 1 hour on a cold line and 6 on a hot one. We give UPVC and SWR 24 hours too (usual practice).

How do I know the joint is good?

The pen mark meets the mouth of the socket, and an even bead of cement shows all round. If it does not, cut the joint out and redo it.

Does the tin go bad?

Yes. Keep the cap tight and away from heat, and brush quickly. Truzo is good for 18 months from manufacture; if the cement is thick or stringy, do not use it.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Hold and wait times are from Prince's CPVC instructions and Astral's Truzo sheet, as written up in our CPVC guide; where they differ the page takes the longer time.

Where the numbers come from

  1. Prince Pipes, SmartFit Plus CPVC instructions: cement brushed on, not by hand, no hammer, hold 1 to 2 minutes, 24 hours before the pressure test, never test with air. Steps in our how to join CPVC pipe.
  2. Astral Pipes, Truzo CPVC solvent cement sheet: hold 30 seconds, minimum 1 hour (cold line) or 6 hours (hot line), 18 months shelf life from manufacture. Both Prince and Truzo cement are yellow.
  3. Charlotte Pipe, solvent welding guide: cut square, use an applicator at least half the pipe's width, apply cement while it is wet, follow the maker's cure time. US guides add a primer step; Prince's CPVC steps do not, so follow the tin you hold.

Not sure which tin? Send a photo of the pipe.

WhatsApp a photo of the pipe and the fitting. We tell you the solvent, the tape and how many tins the job needs, with today's price.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR