Top-floor bathroom under the tank
It has the least height of any outlet: about 0.18 kg/cm² at the shower. It cannot afford to lose any of it in the pipe. Run its branch in 1″ and drop ½″ only at each outlet.
The pipe gets smaller as it feeds fewer taps. The thick part near the tank carries water for the whole house; the thin part near a tap carries water for one tap. Never run ½″ from the tank, and never feed a whole bathroom on ½″.
A roof tank has no pump behind it. All it has is height: about 0.1 kg/cm² for each metre of water above the tap. The pipe decides how much of that little push is left when several taps are open.
Morning bath, the kitchen tap and a flush can all run together, and every drop for them passes through the first few metres below the tank. That is the pipe to make big. Thin it there and every tap in the house shares one narrow throat.
Inside a bathroom, two outlets at a time is normal: the shower and the cistern refilling. A ¾″ branch carries that without the shower going weak when someone flushes.
A tap, a cistern or a basin takes ½″. Its own short run is not where water is lost. Going bigger here only adds cost and makes the wall fittings harder to fit.
Size is not pressure. A bigger pipe does not add push; only height or a pump does. What it does is lose less on the way. For the same flow, a ½″ line loses roughly 13 times as much push per metre as a 1″ line, and a ¾″ line about 3 times as much (standard Hazen-Williams formula, using the bores above). On a top-floor shower that only has 0.18 kg/cm² to start with, that loss is the difference between a shower and a trickle. Pressure at each floor: pressure pump for a house.
Each change in size is made by one fitting. This is the list to give the plumber, or to check against what he has fitted before the walls are closed.
| Where | Size | Fitting | On our shelf |
|---|---|---|---|
| Hole in the tank | 1½″ | Tank nipple, then ball valve and unionThe union lets the valve come off without draining the tank. | Tank nipple, ball valve, union, all 1½″ |
| Just after the valve | 1½″ → 1″ | Reducer 40×25 (Sch 80)Or a 1½×1 bush in a 1½″ socket. | Reducer 40×25 and bush 1½×1 |
| Down the wall | 1″ | Straight pipe, as few bends as the route allows | 1″ UPVC pipe |
| At each bathroom and the kitchen | 1″ → ¾″ | Tee on the down-line, then a 1×¾ bush, or a 1×¾ reducing tee | Tees; 1×¾ sizes we can order |
| Bathroom door | ¾″ | Ball valve on the branchShut one bathroom for repair, keep the rest running. | Ball valve; ¾″ we can order |
| Inside the bathroom | ¾″ → ½″ | ¾×½ reducing tee for each outlet, or a ¾″ four-way tee where three lines split | ¾″ four-way tee; ¾×½ tees we can order |
| At the wall, behind each tap | ½″ | Female-threaded elbow with metal insert (FT elbow), so the tap screws inTeflon tape on the tap thread. | FT elbow 15 mm, Teflon tape |
If your plumber runs 1″ right into the bathroom and drops ½″ from it, that works too: our reducing tee 25×15 and reducing elbow 1×½ are made for exactly that. What does not work is ½″ before the bathroom door. Joining the pipes: how to join CPVC and UPVC pipe.
The tree above suits most two-storey houses in Muzaffarpur. These are the cases where we tell customers to spend a little more on pipe.
It has the least height of any outlet: about 0.18 kg/cm² at the shower. It cannot afford to lose any of it in the pipe. Run its branch in 1″ and drop ½″ only at each outlet.
Every metre and every elbow takes a little push away. A long ¾″ run to the back of the house loses far more than the same run in 1″. Better still, bring the down-line closer.
More outlets open at the same time. Keep the down-line 1½″ all the way from the tank, with a tee and a bush to ¾″ at each bathroom.
These need more push than a roof tank's height gives, however thick the pipe. Plan a booster on that bathroom's line from the start, and lay the line in 1″ so the booster has room to work.
A ground-floor bathroom near the down-line does not need a bigger pipe. It already has a whole storey more height above it, about 0.48 kg/cm² at the shower in a two-storey house. The standard ¾″ branch is plenty.
Answer five questions. You get the down-line, the branch for each bathroom, the push at your weakest shower, and a fittings list to send us. Sizes follow usual practice; heights assume 10 ft floors.
Pipe length depends on your plan; send a photo of the naksha with this list. Prices are filled in from today's pipe rate.
Common in older houses and cheap jobs. The whole house shares a pipe meant for one tap. Change the down-line to 1″; it is usually one straight run and costs less than a pump.
One ¾″ line runs through the first bathroom into the second. Each bathroom should take its own branch from the down-line, with its own valve.
Each elbow costs as much push as a length of straight pipe. Pipe chased round every beam and door adds up. Plan the route on the naksha: straight runs, few bends.
The ¾″ comes to the door and the whole bathroom runs on ½″ from there. Keep ¾″ along the bathroom wall and step to ½″ only at each outlet.
Old GI that has rusted inside behaves like a pipe two sizes smaller. Why we replace it with UPVC: CPVC vs UPVC vs PVC vs GI. Weak water with good pipes: low water pressure, six causes.
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
UPVC pipe 1″ (Ashirvad)Down-line, and 1″ branches₹ 124per pipe UPVC pipe ¾″Branch into each bathroom and the kitchenAsk today's rateper pipe UPVC pipe ½″ (Ashirvad)To each tap, cistern and basin₹ 40per pipe Prince Easyfit Sch 40 pipeLead-free, 3 m · ask which sizes are on the rackAsk today's rateper 3 mWe sell genuine Prince and Ashirvad with a GST bill. ¾″ ball valves, 1×¾ bushes and tees, ¾×½ tees, 1½″ pipe and any size not listed we can order for you; ask on WhatsApp for the time it takes. Today's price for every size: pipe rates. Delivery is charged separately; ask for the amount for your site (delivery).
For a house of up to three bathrooms and a kitchen on one or two floors, usual practice is a 1″ down-line, with the tank nipple, ball valve and union in 1½″ and a 40×25 reducer just after them. Four or more bathrooms, or three floors, take a 1½″ down-line.
Only for the last short piece to each tap, cistern or basin. The line into the bathroom should be ¾″. A ½″ Easyfit pipe has a bore of about 15.8 mm against about 20.9 mm for ¾″, so the ¾″ line has about 1.75 times the water area, and the bathroom doesn't starve when two outlets run together.
No. The push at a tap comes only from the height of the water in the tank above it, about 0.1 kg/cm² for every metre (standard figure). A bigger pipe loses less of that push on the way when water flows, so the tap gets closer to what the height can give. For more than that, raise the tank or fit a booster: see pressure pump for a house.
The top floor. A ground-floor bathroom has a whole storey more height above it. A top-floor shower under a tank on the same roof has only about 0.18 kg/cm², so every bit lost in a thin or long pipe shows. Give the top-floor bathrooms, and the one farthest from the down-line, a 1″ branch.
For Easyfit and other inch-size UPVC, yes: the mm is the nominal bore, so 15 is ½″, 20 is ¾″, 25 is 1″ and 40 is 1½″. Metric pipes are named by the outside instead, so a 20 mm metric pipe is much thinner inside, nearer a ½″, and doesn't fit inch fittings. Read the print on the pipe; more on Easyfit sizes.
No. House CPVC is made in copper-tube sizes, so it is smaller outside than UPVC of the same name, and their fittings don't fit each other. Hot lines from the geyser are CPVC; the cold lines on this page are UPVC. They meet through threaded adaptors: CPVC vs UPVC and the geyser line.
Sch 40 is plenty for a tank line. Prince rates 1″ Easyfit Sch 40 pipe at 31.60 kg/cm² and a 1″ Sch 80 fitting at 26.55, while a roof tank gives about 1 kg/cm² at the ground floor. Sch 40's thinner wall also leaves a wider bore. Use Sch 80 fittings, which is what we keep; details on Easyfit Sch 40 and Sch 80.
Yes, and it is often the biggest gain for the least money. If the line leaving the tank is ½″ or old GI, replacing that one run with 1″ UPVC, with a 1½″ ball valve at the tank, helps every tap. Send a photo of the pipe leaving the tank and we will tell you the fittings.
Twenty years on sites around Muzaffarpur, many of them spent opening walls to find a ½″ pipe where a 1″ should have been. The pipe sizes on this page were checked against Prince's own Easyfit table on 13 Nov 2026. Sizes per bathroom and per house are usual practice and are labelled so; pressure figures are standard physics.
Mark the tank and the bathrooms. We'll send back the pipe sizes, the fittings for each step and today's price on WhatsApp.