हिंदी Call90310 74624
Home›Guides›Sanitary
Bathroom guide · before you buy a WC

S-trap or P-trap toilet: is your drain in the floor or in the wall?

The short answer

Look at the spot where the toilet stands. A pipe mouth in the floor means you need an S-trap WC. A pipe coming out of the wall behind it means a P-trap WC (or a wall-hung one). The letter is the shape of the bend inside the bowl. It does not make one toilet better than the other; your pipe decides, and it cannot be changed without breaking the floor or the wall.

Floor
S-trap WCMeasured wall to pipe centre: 220 or 300 mm.
Wall
P-trap WCMeasured floor to pipe centre: about 180 mm.
4 of 4
Our shelf WCs are S-trapChanel 220, Cinco 300, Celeb, Conventional S-trap. P-trap we order.

Most houses in and around Muzaffarpur have the pipe in the floor. If yours does too, the next question is the distance from the wall: 220 or 300 mm.

The same toilet, two ways out
S-trap WC and P-trap WC side by sideLeft: an S-trap WC. The bend inside the bowl ends in an outlet pointing down into a pipe in the floor; that pipe's centre is 220 or 300 mm from the finished wall. Right: a P-trap WC. Its outlet leaves the back of the bowl straight into the wall, about 180 mm above the floor, and the pipe runs down outside the wall. The floor under it has no hole. S-trap WC pipe in the floor bend inside the S-shaped 220 or 300 mm wall to pipe centre P-trap WC pipe in the wall ≈180 mm no hole in the floor pipe runs down outside the wall floor to pipe centre
Side view, shapes simplified. The blue line is the water path through the bend cast inside the bowl. 220 and 300 mm are CERA's trap distances for Chanel 220 and Cinco 300; about 180 mm is the usual P-trap height (studiomatrx).
How to tell

Three ways to find out, whatever state the bathroom is in

You don't need a plumber for this. Pick the case that matches your bathroom today.

Empty bathroom: a pipe mouth in the floor or in the wall Floor = S Wall = P

The bathroom is bare, or the WC is off

Look where the WC will stand.

An open pipe mouth in the floor, usually capped with a plastic lid or cloth: S-trap. A pipe end sticking out of the wall just above the floor: P-trap. A pipe mouth high up in a bare wall, with a steel frame or space for one, is for a wall-hung WC.

WC still fitted: look behind the bowl Gap behind = S Pipe into wall = P

The old WC is still fitted

Bend down and look behind the bowl, at floor level.

If the foot of the bowl sits on the tile and you see only floor and a gap behind it: S-trap, the pipe is hidden under the bowl. If a short white or grey pipe, or a rubber collar, runs from the back of the bowl into the wall: P-trap.

From downstairs or outside the house bathroom floor above ceiling of room below Through slab = S insideoutside Out of wall = P

You can't get into the bathroom

Upper-floor bathroom: look below it and outside it.

A pipe coming out of the ceiling of the room below, or a sunken slab under the bathroom: S-trap. A thick pipe coming out of the outside wall just above that floor's level and running down the wall: P-trap. This tells you about the drain; confirm at the bathroom before you pay.

Not sure what you are looking at? Take one photo of the floor and wall where the WC goes and send it to us on WhatsApp 90310 74624. We will tell you which it is before you spend anything.

Which WC fits

Tell us your pipe, and see what fits

Two questions. The answer names the toilet from our shelf, or the one we order for you.

Measure from the face of the wall tile to the middle of the pipe. Step by step: 220 or 300 mm.

For your bathroom

Send this on WhatsApp, with a photo

Today's price for each WC is on its page and on the sanitary rate page, with GST bill. Anything not on the shelf we order for you; ask on WhatsApp how long it takes.

Local houses

Why most bathrooms here have the pipe in the floor

It follows from how houses are built around Muzaffarpur, not from any rule. studiomatrx calls the S-trap the traditional Indian arrangement, and ties the P-trap to flats and upper floors where the soil pipe runs along a wall.

1Ground floor

The drain runs under the floor filling to the septic tank. The easiest way into it is straight down, so the plumber leaves a pipe mouth in the floor. S-trap.

2Upper floor, sunken slab

The slab under the bathroom is cast lower, the pipes run in the filling and leave through the side or the slab. The WC still drains downwards. S-trap.

3Upper floor, pipe on the outside wall

No sunken slab and no hole left in the roof below: the soil pipe comes down the outside wall, and the WC drains sideways into it. This is where P-trap WCs turn up here, along with flats built around a pipe shaft.

Foreign shop blogs say S-traps are "outdated" or not allowed. They mean separate trap fittings under sinks in Australian and American codes. In a western WC the trap is cast inside the bowl, and Indian makers sell both: CERA's own range has S-trap and P-trap versions of the same models. Both keep a water seal in the bend; choose by your pipe.

Pipe in the wall

If your pipe comes out of the wall, you have three choices

None of our shelf WCs fit a wall pipe, because their outlet points into the floor. These are the ways forward, best first.

A P-trap floor WC

The usual answer. We order it.
Fits the pipe as it isNo breaking
  • Measure from the floor tile to the centre of the wall pipe. About 180 mm is the usual height (studiomatrx); shop listings sell P-trap WCs as "180 mm".
  • CERA's P-trap WCs include Calibre P (S1020102, 660 × 365 × 770 mm), Callaghan P (S1021105) and Campbell P with soft-close seat (S1021110SL). They are bowls with a separate cistern.
  • CERA's pages do not print the outlet height, so we get the model's drawing and check it against your number before we order.
Send us the height and a photo of the pipe. We confirm the model and the time it takes.

A wall-hung WC

Only if you are redoing the wall anyway.
Needs a frameCistern in the wall
  • Its outlet also goes into the wall, but the bowl hangs on a steel frame and sits higher. The frame and hidden cistern go in before plaster.
  • An existing low P-trap pipe usually has to be raised or reset for the frame.
  • All of it is in one-piece, two-piece or wall-hung.

Make a floor drain

Only when the floor is being broken anyway.
Breaking work
  • A floor drain needs depth under the WC: filling on the ground floor, or a pipe through the slab to the room below.
  • Upstairs that means cutting the slab or raising the bathroom floor. Ask your engineer before cutting a slab.
  • Then any of our S-trap WCs fits; set the pipe to 220 or 300 mm.

About "converter" bendsSome makers sell bends that let a P-trap bowl sit on a floor pipe. The bowl ends up away from the wall and the joint stays in sight, where it can weep; studiomatrx calls such adapters a compromise. The other way round has no fix at all: an S-trap bowl's outlet points into the floor, so it cannot reach a pipe in the wall.

Indian (Orissa) pan

A pan has no trap of its own: it sits on a separate one

The P and S names come from these separate traps. Under an Orissa pan the plumber sets a trap in the floor bed: a P-trap when the pipe then runs sideways under the floor, an S-trap when it drops straight through the slab. We keep the P-trap 125 × 110 mm for this, and order the S.

Sizes, fitting and why a dry trap smells are on the P-trap 125×110 page; the pans are on Orissa pans. Still choosing between a pan and a western WC? Orissa pan or western.

CERA at Rewa Road

The WCs, by where the pipe is

Today's prices are on the sanitary rate page, with GST bill. We sell genuine CERA with a GST bill. Catalogue numbers and sizes are from CERA's own pages. Delivery is charged separately; ask for the amount for your site and see delivery. Does the WC fit the room as well as the pipe? Will this toilet fit. All one-piece models: one-piece WCs.

Questions people ask us

Short answers

Which is better, S-trap or P-trap?

Neither. Both hold a plug of water in the bend inside the bowl, and that water is what keeps drain smell out. The only thing that matters is where your pipe is: floor means S-trap, wall means P-trap.

Are all your WCs S-trap?

All four on our shelf are: Chanel 220, Cinco 300, Celeb and the CERA Conventional S-trap. For a wall pipe we order a CERA P-trap WC; ask on WhatsApp for the time it takes.

How is a P-trap WC measured?

As a height: from the finished floor tile up to the centre of the pipe in the wall. About 180 mm is usual. An S-trap WC is measured along the floor, from the wall tile to the centre of the floor pipe: 220 or 300 mm.

Can I fit an S-trap WC on a pipe in the wall?

No. Its outlet points down into the floor, so it cannot reach a wall pipe. Take a P-trap WC, or move the drain into the floor when the floor is being redone.

Can I change from S-trap to P-trap later?

Only by breaking: a new pipe through the wall for a P-trap, or a new hole in the floor for an S-trap. In a finished bathroom, buy the WC that matches the pipe you have.

My old WC is fitted. How do I know which it is?

Look behind the bowl at floor level. A pipe or rubber collar going from the back of the bowl into the wall means P-trap. Nothing but floor behind the bowl means S-trap. If you are still unsure, send us a photo from the side.

Is the Orissa pan S-trap or P-trap?

Neither by itself. The pan has no trap; a separate trap is set under it in the floor. We keep the P-trap 125 × 110 mm and order the S.

Is a wall-hung WC the same as a P-trap WC?

Both drain into the wall, but a wall-hung bowl hangs on a steel frame with the cistern hidden in the wall, and its pipe sits higher. They are not swapped for each other. See wall-hung or floor WC.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Model names, catalogue numbers, sizes and trap distances here are CERA's own, checked on 13 Nov 2026. The P-trap height is a published typical figure, not a CERA one, so it is checked against the model's drawing before we order. How local houses are drained is site practice.

Where the facts come from

  1. studiomatrx, Floor-mounted toilet India: S-trap outlet down through the floor, traditional Indian arrangement; P-trap outlet into the wall, apartments and upper floors; S-trap measured finished wall to drain centre (220 or 300 mm), P-trap finished floor to outlet centre (around 180 mm); adapters a compromise.
  2. studiomatrx, Plumbing traps in India: P exits sideways, S downward; separate traps under Indian pans.
  3. CERA, Two-piece EWCs: Calibre P Trap S1020102 (660 × 365 × 770 mm), Callaghan P Trap S1021105 (650 × 405 × 770 mm), Campbell P Trap with slim soft-close seat S1021110SL (655 × 370 × 770 mm), with S-trap versions of the same models. Calibre P Trap page: concealed P-trap, no outlet height printed, 10 years residential warranty.
  4. CERA, Chanel 220 and Cinco 300: concealed S-trap at 220 and 300 mm.
  5. Ruhe India, P-trap vs S-trap toilets: floor outlet S, wall outlet P, P-trap 180 mm; rates odour control the same for both.
  6. Store facts: our shelf at Rewa Road (Chanel 220, Cinco 300, Celeb, Conventional S-trap, P-trap 125 × 110 mm). Where houses here drain, and what to look for, is usual site practice.

Send us one photo of the pipe

Floor or wall, with a tape on it if you can. We tell you which WC fits and today's price on WhatsApp.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com