SWR drainage pipe and fittings: the parts that carry toilet and bathroom water out of your house

The short answer

SWR is the grey pipe set for everything that drains: toilet, floor, basin and roof water. The toilet line is 110 mm (shops call it 4 inch). The path never changes: pan, P-trap, 110 mm stack with a door tee at each junction, a cowl above the roof, then the septic tank. No water pressure inside, so the only rule is a steady fall.

We keep the 110 mm tee, tee with door, bend with door, P-trap 125×110, 4″ cowl and 4″ aluminium clamp. The door fittings are ISI and rubber-ring fit.

110 mm
Toilet line and stackWhat shops call 4 inch.
160 mm
Sleeve for the stackWhere it crosses a slab. See the sleeve guide.
40 mm
Basin wasteFloor waste is usually 75 mm.
A two-floor house, drain side only
rain pipe, separate WC WC Septic tank 1 2 3 4 5 6 7 cowlfirst-floor slab tee or bend with door (cleaning cap)
Schematic, not to scale. Numbers follow the water: 1 pan, 2 P-trap, 3 stack, 4 and 5 door tees where the branches join, 6 cowl, 7 bend with door at the foot, then the septic tank. Rainwater goes down its own pipe.
The path of the water

Seven parts, always in this order

Follow one flush from the pan to the tank. Every part on the list below has a number in the drawing above.

Pan or WCThe fixture. An Orissa pan sits over a P-trap; a western WC has its own trap built in.
P-trapHolds a plug of water so drain air cannot come back up. More
110 mm stackThe vertical pipe, outside wall or a shaft, never through a bedroom. All floors share it.
Tee with doorOne where each branch joins the stack. The cap opens for a rod.
Bend with doorAt the foot of the stack, where the line turns to run to the tank.
CowlOn the top of the stack, above the roof, so the traps breathe.
Septic tankA 110 mm run with a steady fall, usually about 1 in 40 (usual practice).

Roof and balcony rainwater goes in its own pipe, not into the toilet stack. Rain filling a toilet stack floods the bathroom in a heavy shower. Two bathrooms on one stack: two bathrooms, one line. Slab holes for the stack: pipe sleeves before dhalai.

Which size

The toilet is 110 mm. Smaller drains use smaller pipe.

Outside diameters drawn to scale. A bigger pipe is not "safer" for a small drain; a basin on 110 mm just wastes money.

Four sizes, outside diameter to scale
40basin waste75floor trap110toilet line, stack160stack sleeve
The dashed ring is the 160 mm sleeve cast into the slab around a 110 mm stack, about 20 mm of gap all round to pack with mortar later.
WherePipe sizeNote
Toilet (pan or WC)110 mmThe 4 inch pipe. Includes the P-trap's drain end (125×110).
Stack, every floor110 mmSame size from top to bottom; never narrower on the way down.
Bathroom floor trap, kitchen floor75 mmUsual practice. Joins the stack through a tee or a reducing fitting.
Basin waste40 mmJoins the floor line or the stack.
Slab sleeve for the stack160 mmA casing, not a drain. Sleeve guide.

The 110 mm set is on our rack. The 75 mm and 40 mm pipe and fittings we order for you; ask on WhatsApp how long it takes. Pipe page: 110 mm SWR pipe.

Type and joint

Two choices when you order: Type A or B, ring or solvent

Type B: soil and waste

Thicker wall. This is the one for the toilet line and the stack.

Type A: ventilation and rain

Thinner wall. For vent pipes and rainwater lines, as Finolex describes the two types under IS 13592.

Rubber-ring (ring fit)Solvent (self fit)
How it sealsA rubber ring in the socketSolvent cement fuses pipe and socket
Heat movementPipe can slide a little in the socketRigid; no give
Open it later?Yes, pull the pipe outNo, cut it out
OursTee with door, bend with door, P-trapSolvent for the plain parts: solvents and tapes

Making a ring joint (usual practice)

Cut square and chamferA slight bevel on the pipe end so the ring is not rolled out of its groove.
Clean the socket and ringGrit under the ring is the commonest cause of a seep.
Mark the depthMark the socket depth on the pipe with a pen.
Wet and pushSoapy water on the pipe, not oil. Push to the mark, then pull back about 10 mm so it can expand.
The parts

What each part does, and what we keep

Each has its own page with the size and how it is fitted.

110 mm single tee

Branches a toilet or floor drain into the stack without a door. Use where nothing will ever need rodding from that spot.

Ours: 110 mm single tee

Tee with door

The same tee with a screwed cap on the side. If the drain chokes, you open the cap and clear it with a rod, instead of breaking the wall.

Ours: ISI, rubber-ring fit

Bend with door

Turns the line (stack to the horizontal run) and carries the same cleaning cap. This is the corner where a choke usually lodges.

Ours: ISI, rubber-ring fit

P-trap 125×110

The water bend under an Orissa pan. The 125 mm end takes the pan, the 110 mm end joins the drain. The water it holds stops drain smell.

Ours: 125×110 mm. Water seal about 50 mm (Ashirvad FAQ)

4″ cowl

The cap on top of the stack, above the roof. It lets air in and out so the traps do not get sucked dry, and keeps leaves, birds and rain out.

Ours: 4″ (110 mm)

4″ aluminium clamp

Holds the stack to the wall so the weight does not hang on the joints.

Ours: 4″ aluminium
One bathroom

What a bathroom with one toilet needs

Counts for a typical ground-floor bathroom joined to a stack. Send us the plan and we count your exact house.

PartHow manyWhy
P-trap 125×1101 per panOne trap for each Orissa pan. A western WC does not need it.
110 mm pipeto lengthPan to stack to septic tank, with a fall. Lengths are cut on site.
Tee with door1 per junctionWherever a branch meets the stack, so you can rod it.
Bend with door1 per stackAt the foot, where the line turns.
Cowl1 per stackOn top, above the roof.
Clamps1 per floor, more on long runsSo the stack hangs on the wall, not on its joints (usual practice).
Mistakes

Four ways a new drain goes wrong

No fall

A flat or backward run holds water and chokes. Check the fall before the trench is filled.

No door at the bend

The foot of the stack is where a choke lodges. A plain bend means breaking the floor to clear it.

Rain into the toilet stack

A heavy shower backs up the bathroom. Give the roof its own pipe.

No cowl

Without a vent, a flush can suck the water out of a trap, and the smell returns.

Before tiling, pour a bucket through and watch every joint. The whole sequence: plumbing stage checklist. A smell already there: leaking joints.

Our shelf

On the rack at Rewa Road

Genuine SWR fittings with a GST bill; the door fittings are ISI. Anything not on the rack we order; ask on WhatsApp for the time. Prices are on the pipe rate board.

Questions people ask us

Short answers

Which pipe size for a latrine?

110 mm, which shops call 4 inch. That is the toilet line and the stack. A basin waste is 40 mm and a bathroom floor trap usually 75 mm.

Type A or Type B for the toilet line?

Type B. It has the thicker wall for soil and waste. Type A is for vents and rainwater (Finolex, under IS 13592).

Ring fit or solvent fit?

Ring fit lets the pipe move a little and can be opened later. Solvent is permanent and rigid. Our door tee, bend with door and P-trap are ring fit. Do not mix a solvent socket and a rubber ring in one fitting.

Do I really need a tee with door?

It costs a little more than a plain tee and saves breaking a wall when a drain chokes. Put one at each junction on the stack, and a bend with door at the foot.

Can I join a 75 mm pipe to a 110 mm fitting?

Not directly. Use a reducing fitting made for it; tell us the sizes on WhatsApp and we send the right part.

What does the cowl do?

It sits on the top of the stack above the roof. It lets air move so water in the traps is not sucked out, and it keeps rain, leaves and birds out.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. The size standards come from the makers' own SWR pages, read on 18 Nov 2026; figures that are only usual site practice are marked as such.

Where the numbers come from

  1. Finolex Pipes, SWR pipes and fittings page: sizes 40 to 160 mm, pipes to IS 13592, fittings to IS 14735, Type A (rainwater, vents) and Type B (soil, waste), ring fit and self fit. Its door fittings are listed in sizes from 63 to 160 mm.
  2. Ashirvad Pipes, SWR fittings pages and FAQ: door tee with a threaded cap for cleaning; P-trap with a 50 mm water seal; vent cowl to protect the stack. Prince Pipes, Ultrafit SWR page: ring or solvent fittings for building drainage.
  3. Sleeve sizes (160 mm for the stack, 75 mm for ½ to 1¼ inch lines) are from our own sleeve guide. "Usual practice" marks a figure from site habit, not a maker's sheet.

Send the bathroom plan. We count the parts.

WhatsApp a photo of your drawing or the open floor. We list the pipe, the tees, the traps and the cowl for each stack, with today's price.