MCB price and range in Muzaffarpur: V-Guard Elegna 6 to 63 A, B and C curve

One page for every MCB question: which rating for which wire, which letter for which load, what is on the shelf and how to ask the price.

The short answer

The MCB protects the wire, so pick its amps from the wire and its letter from the load. 1.5 sq mm: 10 A. 2.5 sq mm: 16 A, never 20 A. 4 sq mm: 20 A. Letter B for lights, fans and plain sockets; letter C for anything with a motor, such as an AC, fridge or pump. We stock V-Guard Elegna 10 A and 20 A; the rest of 6 to 63 A we order.

10 kA
breaking capacityV-Guard Elegna
6–63 A
single-pole rangeB and C curve
5 yr
warrantyV-Guard Elegna
Wire first, MCB below it
Wire carries (amps in a wall pipe)1.5 sq mm13 AMCB B102.5 sq mm18 AMCB C164 sq mm24 AMCB C20
Grey bar: what the wire carries inside a wall pipe. Red mark: the MCB. The MCB always sits below the wire, so it trips before the wire heats.
The rule

The MCB sits below what the wire carries

An MCB is a switch that cuts off by itself when too much current flows. If it is bigger than the wire, the wire overheats before the MCB acts. That is why the wire sets the amps. Many websites put 20 A on 2.5 sq mm wire; V-Guard rates its 2.5 sq mm wire at 18 A inside a wall pipe, and house wiring runs in pipes, so we put 16 A on it.

Add a 30 mA RCCB after the main: the MCB protects the wire, the RCCB protects the person from a current leak. See MCB vs RCCB.
Quick table

Which rating for which circuit

CircuitWireMCBLetter
Lights and fans1.5 sq mm (1 sq mm: B6)10 AB
6 A sockets: TV, chargers1.5 sq mm10 AB
Kitchen, 16 A sockets, washing machine2.5 sq mm16 AC
Geyser up to 3 kW2.5 sq mm16 A double-poleB or C
AC or pump, name plate up to 12 A (most 1 and 1.5 ton)2.5 sq mm, own line16 AC
AC or pump, name plate 12 to 16 A4 sq mm, own line20 AC
Above 16 A on the platesend us the platewe size it with youC
Main switch4 or 6 sq mmdouble-pole, by sanctioned load–

The geyser takes a 16 A double-pole MCB, and its switch goes outside the bathroom: geyser switch. Full chart with working: which MCB for which load; amps per wire size: wire amps chart.

The letter

B or C: the amps stay the same, only the surge changes

How big a surge before it trips (times its rating)0×1×2×3×4×5×6×7×8×9×10×B: lights, fans, plain sockets3 to 5 timesC: motors, AC, fridge, pump5 to 10 times
V-Guard's Elegna sheet gives these bands. A B16 and a C16 both carry 16 A all day.

A motor pulls a burst of current when it starts. A B MCB reads that burst as a fault and trips; a C MCB waits. So C goes on an AC, fridge, pump or mixer circuit. B goes on lights, fans and plain sockets, where it cuts faster on a short circuit in thin wire.

A geyser has no motor, so either letter works; it gets the 16 A double-pole piece. D-curve is for factory motors, not homes. More: B curve vs C curve.

On our shelf

V-Guard Elegna: what we stock and what we order

Elegna is 10 kA, B and C curve, 6 to 63 A single-pole, with a 5-year warranty (V-Guard). Prices are Ask rate here; send us the list and we reply with today's price.

Ask on WhatsApp for the time an order takes. Genuine V-Guard, GST bill with every sale. Check it is genuine: real or fake MCB, and scan the QR on the box.

FAQ

Questions

What is the price of an MCB?

The rate depends on the rating, single or double pole, and the day, so we do not print it. Send the circuits on WhatsApp and we reply with today's price for each MCB.

Which MCB for a house?

One double-pole main, a 30 mA RCCB after it, then single-pole MCBs per circuit: 10 A for lights and fans, 16 A for kitchen, 16 A sockets and 1 or 1.5 ton ACs on 2.5 sq mm, 20 A on 4 sq mm. The table above has the full list.

Which MCB for a 1.5 ton AC?

Look at the name plate. Up to 12 A (most 1 and 1.5 ton splits) takes 2.5 sq mm wire and a 16 A C-curve MCB on its own line. 12 to 16 A takes 4 sq mm and 20 A. Above 16 A, send us the plate.

Which MCB for a geyser?

A 16 A double-pole MCB on 2.5 sq mm wire, for geysers up to 3 kW. Fit the switch outside the bathroom.

Can I put a 20 A MCB on 2.5 sq mm wire?

No. 2.5 sq mm carries 18 A in a pipe, so 16 A is the most it should have. 20 A goes only on 4 sq mm.

Is B or C curve better for a house?

Neither is better. B for lights, fans and plain sockets; C wherever a motor starts. If a C-curve still trips as a motor starts, see MCB tripping.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur. MCB figures are V-Guard's Elegna sheet and wire figures its Classo+ page, checked on 18 Nov 2026; the 16 A rule for 2.5 sq mm is the store's safe choice.

Where the numbers come from

  1. V-Guard, Elegna MCB page and datasheet: B and C curves, 6 to 63 A, 10 kA, 5-year warranty
  2. V-Guard, Classo+ page: in-pipe amps: 1.5 sq mm 13 A, 2.5 sq mm 18 A, 4 sq mm 24 A

Ask today's price

Tell us what you are fitting; we send the list with today's price on WhatsApp.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR