Kitchen plumbing points: the sink's water and waste, the hot line, the RO point, the washing-machine tap, and the drain to the nali
Mark these on the kitchen wall before the plaster, all fed by one ¾″ branch with its own stop cock:
- Sink cold: ½″ UPVC to a wall tap at about 1050 mm, or an angle valve under the counter for a tap mounted on the sink.
- Sink hot, only if you want warm water for utensils: CPVC from an instant geyser above the sink.
- RO point: its own ½″ point and small valve beside the purifier, a socket next to it, and a way down for the reject water.
- Washing-machine tap, if the machine lives here: a tap at about 1000 mm and a standpipe into a floor trap.
- Sink waste: coupling, one bottle trap, 40 mm pipe out through the wall.
- Floor trap and the 75 mm line to a gully trap outside and on to the nali. Never into the toilet line.
Put the sink on an outside wall if the plan allows: the drain then goes straight out instead of under the floor.
Which wall the sink goes on
In most Bihar houses the kitchen is drawn after the bathrooms, and the sink ends up wherever the counter is left. The wall decides how long the drain is, and the drain is the part that blocks.
1Outside wall
The sink, the floor trap and the machine sit on the wall that faces the nali or the side lane. The drain leaves through the wall within a metre or two and is easy to rod from the gully trap.
2Upstairs kitchen
Plan a sleeve in the slab, or better, take the 75 mm pipe out through the wall and down the outside face to a gully trap at the ground. Keep it apart from the bathroom's WC stack.
3Machine and RO near the sink
Both need water and a drain. Grouping them by the sink keeps one floor trap and one short run. The sockets for them go well away from the tap.
Already have the bathrooms planned? The tank-to-bathroom size page gives the down-line; the kitchen takes its own ¾″ branch off it, with a stop cock, so the kitchen tap can be repaired without shutting the house.
What each point needs in the wall
Heights are from the finished floor, for a counter at about 850 mm. They are usual practice, not a maker's rule: if your counter or sink is different, mark the wall from them.
Sink cold water
Every kitchen
- Wall tap or wall mixer: a ½″ FT elbow with brass insert set flush with the tile face, about 200 mm above the counter.
- Tap mounted on the sink or counter: the point goes under the counter instead, with an angle valve and a connection pipe.
- A mixer needs its hot and cold points 150 mm apart (usual practice): ask your tap's box.
Sink hot water
Only if you want it
- A 3 L instant geyser on the wall above the sink, fed from the cold line, with a CPVC pipe from its outlet to the hot point.
- CPVC after the geyser, never UPVC: UPVC is rated to about 60 °C; CPVC to 82 °C (Prince) or 93 °C (Ashirvad).
- Its switch and wire: same rule as a bathroom geyser (16 A double-pole, no socket).
RO purifier point
Every new kitchen
- Its own ½″ point with a small valve, so the RO can be shut for a filter change while the sink still runs.
- KENT's manual: the RO will not start below 0.3 kg/cm², and asks for the tank at least 10 ft above the purifier. A ground-floor kitchen under a roof tank is fine; a first-floor kitchen under a low tank may need a pump.
- Reject water: a pipe that only goes down, to the floor trap or the sink waste. KENT says it must not run higher than the purifier.
Washing machine
If it lives in the kitchen
- A washing-machine tap (with a hose nozzle) just above the machine top.
- The hose hooks into a 40 mm standpipe that drops into the floor trap. Makers ask for the hose outlet high: Haier 80–100 cm for its front-loaders, Samsung 90–100 cm for its top-loaders, with a standpipe at least 5 cm wide.
- Never push the hose into the trap water or into the sink waste.
From the sink to the nali, in order
Kitchen water is greasy, warm and full of food bits. It takes its own line to the nali or soak pit. The toilet line goes to the septic tank and stays separate.
| Part | Size | Why |
|---|---|---|
| Sink coupling with jali | 40 mm | Sits in the sink hole. The jali stops rice and peel before they reach the pipe. |
| Bottle trapthe one trap on the sink line | 40 mm | Holds water against drain smell. Its bottom cap opens for cleaning; a glued bend cannot. |
| Rigid pipe to the wall | 40 mm | studiomatrx asks for at least 40 mm, ideally 50, never the 32 mm basin size. Rigid, not the ribbed flexible pipe: Prayag notes it clogs faster with oil. |
| Floor trap with jalimulti floor trap | 110×75 | For floor-washing water, the RO reject and the machine standpipe. Not the 125 × 110 P-trap: that one is for an Orissa pan. |
| The line outsideSWR | 75 mm | Falls about 1 in 40. A bend with a cleaning door wherever it turns. |
| Gully trap | at ground | A trap with a grating outside the wall; it can be lifted and cleaned without entering the house. |
| Nali or soak pit | — | If there is no lane drain, a soak pit; never the septic tank. |
Fitting the coupling and trap step by step, and keeping grease out: kitchen sink drain. Where both lines meet the lane drain: kitchen and bathroom water to the nali.
Six kitchen plumbing mistakes we see
Bottle trap into the floor trap
Slow sink, gurgling
Two water seals in a row hold a pocket of air. Take the sink pipe past the floor trap into the 75 mm line.
Ribbed flexible pipe that sags
Blocks every few months
Its ribs and dips hold oil. Use a rigid 40 mm pipe with a steady fall from the bottle trap to the wall.
Machine hose pushed into the trap
Drain water back in the drum, smell in clothes
The hose end must stay above the water, hooked into a standpipe at the height the machine's manual gives.
RO reject pipe taken up and over
Reject water runs back into the RO
KENT's manual: the reject pipe must not go higher than the purifier. Plan the RO above the floor trap or sink so its pipe only falls.
Drain laid flat under the floor
Water stands, smell from the sink
Mark the fall on the wall with a string before the floor is filled, and water test it with the plug in, as in the stage checklist.
No stop cock for the kitchen
Every washer change shuts the whole house
A ¾″ ball valve where the kitchen branch leaves the down-line, labelled on the wall.
Pick your points, get the fittings list
Counts are for the points, from usual practice. Pipe lengths depend on your walls, so send the list with a photo or the naksha and we will add the lengths.
Water points in the wall: 0
Fittings for your kitchen
Send this list on WhatsAppPrices are given on WhatsApp with today's rate (Ask rate). Items not on our shelf we order for you; ask for the time it takes. Pressure test before plaster: see the stage checklist.
Our parts for each point
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
Prince Easyfit UPVC pipe ½″ and ¾″Cold lines, Sch 40, 3 mAsk today's rateper 3 m FT elbow ½″ with brass insert, MTA, FTAEach tap point in the wallAsk today's rateper piece Reducing tee ¾ × ½, elbows, end capsSch 80 fittingsAsk today's rateper piece Prince UPVC ball valve ¾″The kitchen's own stop cockAsk today's rateper piece CPVC pipe, fittings, Truzo solventGeyser to hot pointAsk today's rateper length PVC solvent and Teflon tapeUPVC joints and tap threadsAsk today's rateper pieceToday's price for each: pipe and fitting rates. We sell genuine Prince fittings with a GST bill. Delivery is charged separately; ask for the amount for your site (delivery). Sinks, taps, geysers and purifiers: we can order them for you; ask on WhatsApp for the time it takes.
Short answers
What size pipe for the kitchen sink drain?
40 mm from the bottle trap to the wall (studiomatrx: at least 40, ideally 50, never the 32 mm basin size), then a 75 mm SWR line outside with a fall of about 1 in 40 to the gully trap.
Can the kitchen drain join the toilet line? (rasoi ka paani toilet line mein)
No. The toilet line goes to the septic tank; kitchen grease chokes it, and a dry trap would bring its gas into the kitchen. Give the kitchen its own 75 mm line to a gully trap and the nali, or a soak pit.
Does the kitchen need a floor trap?
Yes, if the floor is washed, the RO reject or a washing machine drains there. Put it outside the sink cabinet so floor water reaches it. The sink itself drains through its own bottle trap, not into the floor trap.
At what height is the kitchen tap point?
Usual practice: a wall tap or wall mixer about 1050 mm from the finished floor for an 850 mm counter, so the spout clears the sink. A tap on the sink needs its point under the counter at about 450 mm with an angle valve.
Where does the RO's waste water go?
Into the floor trap or the sink waste, through a pipe that only runs down. KENT's manual says the reject pipe must not go higher than the purifier, and its Sterling manual keeps the drain within 3 m.
Does a kitchen need hot water?
Not always. If you want it for oily utensils, a small instant geyser above the sink with a CPVC pipe to a wall mixer is the simplest. UPVC is not for hot water.
Should I fit a grease trap?
For a house kitchen, a jali in the sink, a cleanable bottle trap, a rigid pipe with a fall and a cleaning door at each turn usually do the job. Never pour frying oil down the sink. Blocked already: kitchen sink jam.
Twenty years on sites around Muzaffarpur. Heights and the fall are usual practice on local sites and are labelled so; RO, machine and pipe figures are from the makers named below.
Where the facts come from
- KENT, Supreme RO manual: does not start below 0.3 kg/cm² inlet pressure; source tank at least 10 ft above the purifier. KENT Sterling Plus manual: drain within 3 m. KENT Prime TC handbook: reject pipe not higher than the purifier.
- Haier, front-load drain hose installation: outlet 80–100 cm. Samsung, top-load drain hose guide: 90–100 cm, standpipe at least 5 cm. Your model's manual decides.
- Prince Pipes, CPVC vs UPVC: CPVC to 82 °C on Prince's SmartFit Plus page (93 °C is Ashirvad's rating), UPVC about 60 °C. Prince Ultrafit SWR multi floor trap 110 × 75 with jali, as on our bathroom pages.
- studiomatrx, Kitchen plumbing cost India: sink waste at least 40 mm, ideally 50; fall about 1 in 40; removable bottle trap.
- Prayag, Kitchen plumbing checklist: waste at least 40 mm; ribbed flexible pipes clog faster with oil.
- IAPMO, Code Spotlight on double trapping, and the International Plumbing Code section 1002.1: a fixture shall not be double trapped; air between traps slows drainage.
- Pipe sizes from the house down-line, ¾″ kitchen branch and ½″ last runs: our tank-to-bathroom size page. Heights and the 150 mm mixer spacing: usual practice.
Send us your kitchen wall
A photo or the naksha with the sink marked. We will mark the points with you and send the fittings with today's price, before the plaster.