हिंदी Call90310 74624
Home›Guides›Pumps
Pump guide · boring, sump, well

Self-priming or submersible: which pump for your boring

The short answer

A self-priming (monoblock) pump sits on top and pulls water up a pipe; a submersible hangs in the water and pushes it up. Pulling has a hard limit. If the water in your boring stays within about 7 m (23 ft) of the pump even in May, take a self-priming pump: it is cheaper and any mistri can open it. Deeper than 7 m (23 ft), only a submersible works, and only in a boring 3 inches wide or more.

7 m
What we plan on, any pump on topBeyond that we advise a submersible.
6–8 m
What makers printV-Guard: about 6 m for a normal pump, up to 8 m for shallow-well; Crompton: up to 8 m.
3 inch
Narrowest boringfor a home submersible (V-Guard: 3, 3.5 and 4 inch).
Pulls from above vs pushes from below
Self-priming pump and submersible pump compared by depth Left: a self-priming pump on the ground pulls water up a suction pipe from a boring where the water stands about 5 m down. A red dashed line at 7 m marks the most we plan for any pump on top; makers print 6 m for ordinary self-priming pumps and up to 8 m for high-suction ones. Right: a submersible pump hangs about 22 m down in a 3 or 4 inch boring, below water that stands about 14 m down, and pushes water up a column pipe; a flat cable runs up to a control panel on the wall. 0 m 4 8 15 20 25 6 mordinary 7 mour limit,any pumpon top water at 5 m SELF-PRIMING on top · PULLSpump on the groundfoot valve /pipe endto tank water: 14 m SUBMERSIBLE in the water · PUSHEScontrol panelto tankpump,3" or 4"flat cablebeside thecolumn pipe
Not to scale across. Depth scale in metres (1 m ≈ 3.3 ft). The 7 m line is what we plan on; V-Guard and Crompton print 6 m (ordinary) and up to 8 m (high-suction); air pressure caps suction at about 10.3 m even for a perfect pump, and every bend and leak takes some away. A submersible has no such line: it only needs enough head.
The number that decides

Not how deep the boring is: how deep the water stands

Three depths, one boring
Total boring depth versus water level in November, in May and while pumping A boring 150 ft deep. In November the water stands about 8 ft down. In May it falls lower, say 15 ft. While the pump runs, the level near the pipe drops a few feet more. The pump must pull from the lowest of these, which is far less than the 150 ft total depth. November: 8 ft May: 15 ft May, pump running: 18 ft this is the one that counts pull boring 150 ft: the borer's number The pump only seesthe top few metres.The deep part of the boringis for clean, steady water.
Example figures, not a forecast for your boring. CGWB's district profile for Muzaffarpur (2011 readings) gives pre-monsoon water levels of roughly 2 to 7.6 m below ground, shallower after the rains. Your boring can be different; measure it.

Everyone asks "boring 100 feet hai, 150 feet hai". For choosing between these two pumps that number hardly matters. What matters is how far below the pump the water stands, in the driest month, with the pump running. Three ways to find it:

1. Ask the borer

He noted where he struck water and where it settled. Ask for the water level, not the boring depth. Ask what it does in May.

2. Measure it

Where the boring pipe is open at the top, lower a string with a small weight tied on until it comes up wet. Mark the string at ground level and measure. Usual practice; do it in May for the honest figure.

3. Watch the old chapakal

An ordinary suction hand pump (the kind with no rod going down the boring) works on the same physics as a self-priming pump. If it gives water freely in May, the water is within suction reach.

One more figure from the same visit: the boring's widthMeasure the pipe at the top, or ask the borer. A 1¼ to 2 inch pipe was made for a hand pump: only a pump on top fits it. A 3 inch or wider casing can take a submersible. More on casing: casing depth in north Bihar · casing pipe.
Find your band

Water level in May, and the pump that goes with it

Measured from where the pump will sit down to the water, with the pump running. Each band is the maker's figure, rounded down a little for the pipe and the bends.

Up to 5 mabout 16 ft
Self-priming pump

Comfortably inside an ordinary pump's reach. Our Nova pumps are for this. Which HP is a separate question: 0.5 HP or 1 HP.

5 to 7 m16–23 ft
Self-priming, check the plate

7 m is our planning limit for any pump on top (makers print about 6 m for an ordinary pump, up to 8 m for high-suction). Read the suction figure on the pump's nameplate or box, keep the suction pipe short and straight, and every joint airtight.

7 to 8 m23–26 ft
Submersible

Past our 7 m limit. A shallow-well (high-suction) pump rated "up to 8 m" might reach, with nothing to spare, so if the boring is 3 inch or wider we advise a submersible. In a narrower boring the high-suction pump is the one that fits.

Over 8 mmore than 26 ft
Submersible

No pump on top will pull it, whatever its HP. You need a submersible and a boring at least 3 inch wide. In a narrower boring the answer is a new, wider one.

Sitting the pump lower in a pitSome fitters put a self-priming pump in a pit beside the boring to win a metre or two. It works, but the pit fills in the rains and a flooded motor burns. If you do it, line the pit, give it a drain or a cover, and keep the pump's switch above flood level. For how far suction really reaches with long pipes and bends: how deep a self-priming pump can pull.
The two sets, side by side

What you actually buy for each

A self-priming pump is one box and a few fittings. A submersible is a system: pump, pipe, cable and panel, all lowered into the boring. The example figures are the makers' own, from their product pages.

1 2 3 4 to tank

ASelf-priming (monoblock) pump

Water within 7 m (makers print 6 m, or 8 m for high-suction)
  1. Suction pipe into the boring, with a non-return or foot valve at its end if the pump's manual asks for one. V-Guard: regenerative self-priming pumps don't need one, centrifugal pumps need an ISI foot valve. Every joint airtight: one air leak and it stops lifting.
  2. The pump on a firm base, under a cover, out of flood water. A mistri can open it on the spot.
  3. Delivery pipe to the tank with a union and a ball valve at the pump, so it comes off for repair. Pipe size from the pump's ports: pipe for a pump.
  4. Its own switch, MCB and earth. Up to 1 HP: 2.5 sq mm wire, 16 A C-curve MCB, earth the same size as phase. Wire for a motor.
Maker's example: Crompton's shallow-well range, 0.5 and 1 HP: suction up to 8 m, 180–260 V. Our Nova NH01 (0.5 HP) and NF01 (1 HP): read the suction and head figures on the nameplate before you rely on them.
1 2 3 4 5 to tank

BSubmersible pump

Water deeper than 7 m, boring 3 inch or wider
  1. Casing wide enough for the pump: 3, 3.5 or 4 inch for a home pump (V-Guard). It keeps the boring from caving in.
  2. Column pipe from the pump to the top, with a clamp and cap at the boring head. It carries the pump's weight too.
  3. Flat cable taped to the column pipe, sized by the pump maker for your depth.
  4. The pump, hung well below the lowest May water level and clear of the bottom silt.
  5. Control panel (starter) on the wall: switch, capacitor and protection for the motor in the boring. Ashirvad lists casing, column pipe, flat cable, pump and panel as the parts of a boring set.
Maker's examples: Crompton 3W12AP1D, 3 inch, 1 HP (0.75 kW): up to 52 m, 900–3120 L/h, 160–240 V. Crompton 4W1/10-BUE-D, 4 inch, 1 HP: up to 56 m, 10–100 L/min, 160–240 V.
What you care aboutA · self-primingB · submersible
Water level it can reachwe plan on 7 m (makers print 6–8 m)no suction limit; as deep as its head allows
Boring width neededany, even a 1¼ inch hand-pump boring3 inch or more
Also works fromsump, open well, tank, pondboring; open-well models for wells and sumps
Parts besides the pumppipe, valve, union, wirecasing, column pipe, flat cable, control panel, rope or clamp
When it failsmistri opens it on the spotthe whole set is pulled up the boring; needs a team
Noiseyou hear it near the pumpalmost silent, it is under water
Priming, air leakscan lose prime if a joint lets air inno priming; sits in water
Floodskeep it above flood levelpump is under water anyway; keep the panel high
Voltage range (examples)Crompton shallow-well: 180–260 VCrompton 3" and 4": 160–240 V
Price of the full setAsk rateAsk rate

Neither one is a pressure pump. Both fill the roof tank. For weak showers under a full tank you want a booster on the tank line: pressure pump for home.

Quick picker

Two answers, and we tell you which pump

Water level and boring width settle the type. The HP comes after, from your floors and bathrooms.

"Below the pump" means from where the pump will sit down to the water. If the pump sits on a platform, add its height.

What we would fit

—
—
    Pump and partsAsk rate
    Send this to Sashikesh on WhatsApp

    Nova self-priming pumps are on the shelf. A submersible and its panel, pipe and cable we can order for you; ask on WhatsApp for the time it takes.

    What goes wrong

    Four mistakes we see at the counter

    0.5 HP 2 HP both stop here

    Buying more HP to pull deeper

    You see: a new 1 HP that lifts no better

    HP pushes water higher after the pump. It does not pull from deeper below it. Past the suction line, only a pump in the water works.

    air in suction pipe

    A suction joint that lets air in

    You see: the pump runs but no water comes

    On the suction side, a joint that doesn't drip can still let air in. Crompton: air leaks stop priming. Use solvent cement and Teflon properly, and keep the suction pipe as short as you can. More: pump not lifting water.

    no panel

    A submersible with no control panel

    You see: a burnt motor, 20 m down

    The panel holds the starting parts and protects the motor you can't see. Skipping it saves little and risks the most costly part. Fit the panel the maker names for that pump.

    150 ft? water: 8 ft

    Choosing by the boring depth

    You see: a costly submersible where a pump on top would do

    A deep boring with water near the top often needs only a self-priming pump. Ask for the water level in May, then decide.

    For this job

    The pump, and what goes with it

    Foot valves, non-return valves and any pump or size not listed we can order for you; ask on WhatsApp for the time it takes. Today's prices: pipe rates.

    Read next

    Questions people ask us

    Short answers

    Which is better for a home, self-priming or submersible?

    Neither in general. If the water stays within about 7 m of the pump even in May, a self-priming pump is cheaper and easier to repair. Deeper than 7 m, we advise a submersible in a boring at least 3 inches wide.

    How deep can a self-priming pump pull? (motor kitne feet tak kheenchega?)

    V-Guard gives about 6 m (20 ft) for normal self-priming pumps and up to 8 m (26 ft) for shallow-well pumps; Crompton says up to 8 m for its shallow-well range. We plan on 7 m for every pump on top and take a submersible beyond that. Air pressure caps it at about 10.3 m even in theory. Read your own pump's nameplate; long suction pipes and bends take some away (details).

    Will a bigger HP pump pull from deeper?

    No. HP pushes water higher and faster after the pump. A 1 HP and a 0.5 HP of the same type stop at about the same suction depth. Choosing the HP is about your tank height and bathrooms: 0.5 HP or 1 HP.

    Boring 150 feet hai. Do I need a submersible?

    Not because of the 150 feet. What counts is where the water stands, in May, with the pump running. CGWB's Muzaffarpur profile (2011 readings) shows pre-monsoon levels of roughly 2–7.6 m below ground, so many deep borings here still suit a pump on top. Ask the borer or measure it.

    Can a submersible go in a 1½ or 2 inch boring?

    No. Home submersibles are made for 3, 3.5 and 4 inch borings (V-Guard). A hand-pump boring takes only a pump on top. If the water there is too deep for suction, the answer is a new, wider boring with casing.

    Which one lasts longer?

    Makers don't publish a fair comparison. The real difference is repair: a self-priming pump is opened by a mistri at the pump; a submersible has to be pulled out of the boring with its pipe and cable. Clean water, steady voltage and dry-run protection matter more than the type.

    Our voltage drops in the evening. Which is safer?

    Check the maker's range on the box: Crompton gives 180–260 V for its shallow-well pumps and 160–240 V for its 3 and 4 inch submersibles. If the voltage often falls below that, run the pump at other hours or ask us about a stabiliser. See low voltage.

    Do you sell submersible pumps?

    Nova 0.5 HP and 1 HP self-priming pumps are on our shelf. A submersible, its control panel, column pipe and flat cable we can order for you; ask on WhatsApp for the time it takes. Send the water level and bore width first so we order the right one.

    Sashikesh Kumar
    Diploma in Electrical, Tashya Ventures

    Looks after wiring, MCBs, fans, inverters and pumps at our Reva Road store, Muzaffarpur. The suction and bore figures on this page were checked against V-Guard's buying guide and Crompton's product pages on 13 Nov 2026. The depth bands round the makers' figures down; ways to measure the water level are usual practice and labelled so.

    Where the numbers come from

    1. V-Guard, buying guide for water pumps: normal self-prime pumps about 6 m suction; shallow-well pumps up to 8 m; tube-well submersibles for 3, 3.5 and 4 inch borings; centrifugal pumps need an ISI foot valve, self-prime pumps don't.
    2. Crompton, shallow-well pumps: suction lift up to 8 m, 0.5 and 1 HP, 180–260 V.
    3. Crompton, 3W12AP1D 3" submersible: 1 HP / 0.75 kW, max 52 m, 900–3120 L/h, 160–240 V.
    4. Crompton, 4W1/10-BUE-D 4" submersible: 1 HP / 0.75 kW, max 56 m, 10–100 L/min, 160–240 V.
    5. Crompton, centrifugal vs submersible: surface pumps are limited by suction lift and may need priming; submersibles avoid it. What is priming: air leaks stop priming; dry running damages seal and bearings.
    6. Ashirvad, drawing groundwater for your home: casing, column pipe, flat cable, submersible pump and control panel.
    7. Astral, how to select a submersible pump for a borewell: borings under 50 m / 50–100 m / over 100 m; 0.5–1 HP for homes.
    8. CGWB, district groundwater profile for Muzaffarpur (2011 readings): pre-monsoon depth to water roughly 2–7.6 m below ground.
    9. Standard figure: air pressure at sea level holds up about 10.3 m of water, the most any suction pump could lift in theory.
    10. Wire and MCB rule: V-Guard Classo+ table (2.5 sq mm in a wall pipe carries 18 A, so a 16 A MCB); earth same size as phase (IS 732).
    11. Measuring with a string, the chapakal check, the pit warning and the depth bands: usual practice, labelled on the page.

    Send us two numbers

    Water level in May and the width of your boring pipe, plus how many floors up the tank is. Sashikesh will tell you which pump, which HP and the full list with today's price.

    TASHYABUILDING SOLUTIONS · MUZAFFARPUR
    WhatsApp 90310 74624tashyaventures.com