हिंदी Call90310 74624
Home›Guides›Waterproofing
Waterproofing guide · in the mix

How much WP+200 per bag of cement: 200 ml, how to mix it, and litres for a slab, plaster or plinth

The short answer
200 ml in every 50 kg bagIn every batch of the job. Litres = bags × 0.2, so 5 bags take 1 litre.
  1. Dry mix + half the water
  2. 200 ml into the other half
  3. Pour it all in
  4. Plain water only if stiff

That is UltraTech's own method for its Weather Pro WP+200. Never pour it on dry cement, and never skip a batch: the batch without it is where the roof leaks.

1 L
Covers 5 bags5 L covers 25, 10 L covers 50, 20 L covers 100.
19.2 L
1000 sq ft roof, 5 inch96 bags of cement, so one 20 L can.
10–15%
Less waterUltraTech's figure. Never above 25 L for one bag.
One bag, one measure
WP+200 dose: one 50 kg bag of cement takes 200 mlOne 50 kg bag of cement equals 200 ml of WP+200. Five bags equal one litre. Packs: 1 L covers 5 bags, 5 L covers 25, 10 L covers 50, 20 L covers 100.50 kg=200 ml1 bag of cement200 ml of WP+20050 kg, any UltraTech baginto the second half of the water=1 L5 bags1 litrePACK · BAGS IT COVERS1 L5 bags5 L25 bags10 L50 bags20 L100 bags
Dose and pack sizes: UltraTech Weather Pro brochure. UltraTech also makes 200 ml, 50 L and 100 L packs; we order those for you.
How to mix it

Into the water, in two halves, never on dry cement

This is UltraTech's method, set out for a site mixer that takes one bag a batch. Mixing by hand on a platform works the same way: dry first, then the water in two halves.

How to mix WP+200 in four stepsStep 1: dry materials and bucket A, half the water, mixed 2 to 3 minutes. Step 2: 200 ml of WP+200 stirred into bucket B, the other half. Step 3: all of bucket B poured into the mixer. Step 4: plain water only if the mix is too stiff, never more than 25 litres per bag. Never pour WP+200 on dry cement.1Dry mix + bucket Acement, balu, gitti + half the water · 2–3 min2200 ml into bucket Bthe other half of the water · stir well3Pour in all of bucket Bthe full dose reaches the batch4Too stiff? Plain watera little at a timeAA ≈ 11 L waterB+200 mlB ≈ 11 L waterstir till evenBall of it, nothing left in the bucket≤ 25 L per bagneeds 10–15% less water (UltraTech)Never on dry cementIt soaks into one spot.That spot gets far too much,the rest of the batch gets none.
  1. Dry mix with half the water

    Cement, balu and gitti go in dry, then bucket A, about half the water for the batch. Run the mixer 2–3 minutes. That is UltraTech's step 1.

  2. 200 ml into bucket B

    Measure 200 ml for the one bag in this batch and stir it into the other half of the water. Two bags in the batch, 400 ml.

  3. Pour in all of bucket B

    All of it, so the whole dose reaches the batch. Then mix for the usual time.

  4. Plain water only if it is too stiff

    UltraTech says the mix needs 10–15% less water with WP+200. So start low, and if the vibrator can't work it, add plain water a little at a time. Never add it back to "the old wetness".

Water for one bag of slab concreteLitres
Most allowed, roof open to rainIS 456: water-cement ratio 0.50 × 50 kg25 L
Plan with WP+20010–15% less, UltraTech21–22 L
Bucket A, plaingoes on the dry mix first≈ 11 L
Bucket B, with 200 ml WP+200goes in second, all of it≈ 11 L
Measuring 200 ml on site Pour a 1 L pack into a clean 1 L bottle and mark it in five equal parts: one mark, one bag. Or mark a mug once against a measuring jug and keep it by the mixer. Don't measure with a cap or "by eye".
Plaster and brick mortar No fixed water figure here. Same idea: half the water in first, 200 ml for each bag of cement in the other half, then plain water until the mason says it works. Count the bags of cement in the mortar, not the sand.
How many litres

Litres and packs for the usual jobs

Bags are worked out the way our cement calculator does it, with no spare added. Litres are bags × 0.2. Packs are the mix that leaves least over.

JobCementWP+200
Roof slab, 1000 sq ft, 4 inchM20, 1:1.5:377 bags15.4 L10 L + 5 L + 1 L
Roof slab, 1000 sq ft, 5 inchM20, 1:1.5:396 bags19.2 L20 L
Roof slab, 1000 sq ft, 6 inchM20, 1:1.5:3115 bags23 L20 L + 3 × 1 L
One-room lanter, 12 × 10 ft, 5 inchor the stair cabin12 bags2.4 L3 × 1 L
Outside plaster, 1000 sq ft of wall20 mm, 1:4, rain-facing walls18 bags3.6 L4 × 1 L
Inside plaster, 1000 sq ft12 mm, 1:6, bathroom and ground-floor walls8 bags1.6 L2 × 1 L
Plinth beam, 9 × 12 inch200 running ft, a 1000 sq ft house35 bags7 L5 L + 2 × 1 L
DPC band on the plinth wall40 mm on a 9 inch wall, 200 running ft5 bags1 L1 L
Crack and patch mortar, old roofwith the Hi-Flex repairas used200 ml a bag1 L

Beams, chhajja and stairs add bags to a slab. Keep 2–3 spare bags of cement on site and 1 L of WP+200 with them, so a short-fall never means a batch without it. If the slab is Weather Plus cement, it takes no WP+200 (see below). Roof, plaster and tank together: waterproofing calculator.

Your job

Bags to litres to packs, for your size

Pick the job and put in the size from your drawing. You get the bags of cement, the litres of WP+200 and the packs to buy.

—

Your list

Cement, 50 kg bags——
Weather Pro WP+200—200 ml for every 50 kg bag (UltraTech)—
Mixing water, most—25 L a bag at most (IS 456); with WP+200 plan about 21–22 L.
Material totalAsk rate
Send this list on WhatsApp

Concrete: M20, 1:1.5:3, dry volume = wet × 1.54. Plaster: × 1.33 plus 20% for uneven walls. 1 bag = 1.23 cft (usual practice). Prices are filled in from today's rate. Balu and gitti too: cement, sand and gitti calculator.

Every bag, every batch

The batch without it is the spot that leaks

A slab is poured one mixer batch at a time, each batch a patch of the roof from top to bottom. WP+200 protects only the batches it went into. UltraTech's guide says it plainly: a lower dose will not give effective waterproofing.

A slab poured in 96 batches with one batch missedPlan of a 1000 sq ft, 5 inch slab as 96 mixer batches. All have WP+200 except one. In the section below, rain soaks through the untreated batch and drips into the room.1000 SQ FT ROOF, 5 INCH: 96 BATCHES SEEN FROM ABOVE1 square = 1 mixer batch = 1 bag + 200 mlbatch with WP+200batch without itTHE SAME SLAB IN SECTIONthe leak comes here
Drawn for a 1000 sq ft, 5 inch slab: 96 bags, so 96 one-bag batches. Batch size: usual practice for a one-bag site mixer.

1One batch missed

The bottle ran out, or the boy at the mixer forgot. That square is plain concrete in a treated roof, and the monsoon finds it. Keep a spare litre on site before the pour starts.

2The second pour without it

If the dhalai stops and restarts, the join is already the weakest line in the roof. Keep the same dose on both sides of it. What to do at the join: if the dhalai stops halfway.

3"Only in the last few batches"

Some sites save money by putting it in the batches at the end, "on top". There is no top layer: those batches are just the last patch of roof. Every batch, or the money is half wasted.

17 bags so far3 L in · next litre at 20

The board trick: a stroke for every bag that goes in the mixer, and a 1 L bottle emptied beside every five strokes. At the end, count empty bottles against empty bags: 96 bags, 19.2 L.

Where it goes

Where WP+200 goes in a house, and what it doesn't do

UltraTech lists every cement job, from foundation to plaster. These are the places in a Muzaffarpur house where it earns its cost.

Where WP+200 goes in a houseSection of a house with numbered parts: 1 roof slab, 2 Hi-Flex coat and screed on top, 3 plinth beam or DPC band, 4 outside plaster, 5 parapet and chhajja, 6 bathroom floor base, 7 foundation concrete.1254367ground level
Yellow parts have WP+200 in them. Not to scale. Areas of use: UltraTech Weather Pro brochure.
  1. 1Roof slab: WP+200 or Weather Plus, not bothWP+200 in Premium, Super or plain PPC concrete, or a Weather Plus slab without it. UltraTech publishes no advice on using the two together. Waterproofing at chhat dhalai
  2. 2Hi-Flex on top, either wayTwo coats crosswise once the slab is cured and dry, then a screed. WP+200 does not replace it. How much Hi-Flex
  3. 3Plinth beam or DPC bandStops damp climbing up from a wet or flood-prone plot into the walls. Plinth and DPC
  4. 4Outside plasterIn the mortar on walls that take the rain. WP+200 in plaster and brickwork
  5. 5Parapet and chhajjaWet from three sides every monsoon. Plaster them with it.
  6. 6Bathroom and kitchenThe floor base and the wall plaster around the wet area.
  7. 7Foundation concreteUltraTech lists foundation concreting first. Worth it where the water table is high.

It doesn't cure an old leak

It works only inside new concrete or mortar. A roof already leaking needs its cracks filled and a coating: roof leaking.

It doesn't replace curing

UltraTech's guide asks for good practice "including curing". Keep the slab wet at least 10 days, 14 in hot dry weather (IS 456). Curing after dhalai

It doesn't rescue a wet mix

Too much water, no vibrator, honeycombs at the edges: water gets through those whatever is in the mix. Keep to 25 L a bag at most.

It isn't a coating

Painting it on a roof or wall does nothing. It goes into the mixing water and nowhere else.

Before the pour: send photos of the sariya on WhatsApp before dhalai and we'll check them with you. Bring the WP+200 with the cement, not on the morning of the pour.

What goes wrong

Six ways the WP+200 gets wasted

We hear all of these after the first monsoon, usually with "but we put the chemical in".

Poured on dry cement

You get: one wet lump, the rest untreated

It soaks into one spot of the heap. That spot gets far too much and the rest of the batch gets none. UltraTech: into the second half of the water, every time.

200 ml2 × 200 ml

"A little extra, to be safe"

You get: a bigger bill, no better roof

UltraTech gives one dose, not a range. More liquid does not make the concrete denser. A short dose is the real danger, so measure, don't pour by eye.

200 ml

Mixed into the water drum

You get: some batches dosed, some not

The dose follows the cement, not the water. Water per batch changes through the day, so a drum-mix lands unevenly. One measure per bag, into bucket B.

+> 25 Lfor one bag

Water topped back up

You get: weak, porous concrete

With WP+200 the mix works with 10–15% less water. Adding water back to the old wetness throws that away and can push past 25 L a bag, the IS 456 limit for a roof.

10–14 days wet

"Chemical dala hai", so no curing

You get: fine cracks across the roof

WP+200 does not replace curing. Keep the slab wet at least 10 days, 14 in hot dry weather. Cracks let water past any mix.

WEATHER PLUS+WP+200one orthe other

Weather Plus and WP+200 together

You get: money spent twice

Use one or the other in the slab. UltraTech gives no advice on combining them. Put that money into Hi-Flex on top instead.

Questions people ask us

Short answers

How much WP+200 for one bag of cement? (WP+200 kitna dale)

200 ml in each 50 kg bag, as UltraTech's Weather Pro brochure says. Five bags take 1 litre. The dose is the same for concrete, plaster and brick mortar.

How many litres for a 1000 sq ft roof slab?

For the slab alone in M20: about 15.4 litres at 4 inch (77 bags), 19.2 litres at 5 inch (96 bags) and 23 litres at 6 inch (115 bags). Beams, chhajja and stairs add more. Use the calculator above for your size.

How do I mix it?

Mix the cement, sand and aggregate with half the water for 2 to 3 minutes. Stir 200 ml of WP+200 per bag into the other half of the water, then add all of it. Never pour WP+200 on dry cement. The mix needs 10 to 15% less water, so add plain water only if it is too stiff.

What happens if I add more than 200 ml per bag?

Nothing useful. UltraTech gives one dose, not a range. Extra liquid costs money and does not make the concrete denser, so keep to 200 ml.

Can I use it in only some bags, or only the top of the slab?

No. Each mixer batch is a patch of the slab, top to bottom. A batch without WP+200 is a patch of plain concrete in a treated roof, and that is where the leak shows. UltraTech also warns that a lower dose does not give effective waterproofing.

Is the Dr. Fixit LW+ dose the same?

Yes, Dr. Fixit Pidiproof LW+ is also 200 ml per 50 kg bag, so a mason who knows LW+ can use WP+200 the same way. One difference: Dr. Fixit puts it into the last third of the mixing water, UltraTech into the second half. Follow the maker of the bottle you are using. More in WP+200 vs Dr. Fixit LW+.

Can I use WP+200 with Weather Plus cement?

In the slab, use one or the other. UltraTech publishes no advice on using both together. Either way, the roof gets two coats of Hi-Flex once it is cured and dry.

Does WP+200 replace curing or a roof coating?

No to both. Keep the slab wet at least 10 days, 14 in hot dry weather, and coat the roof with Hi-Flex after curing. WP+200 makes the concrete itself resist water; it does not do those jobs.

Mr Mustafaa
Paint Engineer, Tashya Ventures

Paint Engineer at our Reva Road store, Muzaffarpur, and the man customers ask about waterproofing. Every number on this page was checked against UltraTech's own Weather Pro sheets on 12 Nov 2026. Where makers differ, the page says so.

Where the numbers come from

  1. UltraTech, Weather Pro waterproofing brochure (PDF): 200 ml for every 50 kg bag; mix with only 50% of the water for 2–3 minutes; WP+200 into the remaining 50%; use in foundation concrete, beams, columns, brick joining, internal and external plaster; packs 200 ml, 1, 5, 10, 20, 50, 100 L.
  2. UltraTech, Weather Pro application guide (PDF): water requirement decreases by 10–15%; a lesser dosage will not give effective waterproofing; follow good practice including curing; 5 bags = 1 L.
  3. Dr. Fixit, Pidiproof LW+ technical data: 200 ml per 50 kg bag; LW+ into the last 1/3 of the mixing water; water-cement ratio below 0.5.
  4. IS 456:2000: water-cement ratio at most 0.50 for reinforced concrete exposed to rain (25 L for a 50 kg bag); clause 13.5.1, wet curing at least 10 days for blended cement, 14 suggested in hot dry weather.
  5. Bag counts: our cement, sand and gitti calculator method (M20 1:1.5:3, dry volume × 1.54 for concrete, × 1.33 plus 20% for plaster, 1 bag = 1.23 cft), the same figures as cement for chhat dhalai.

Send us your slab size

We'll send back the cement bags, the litres of WP+200 and the packs, with today's price, on WhatsApp.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR