हिंदी Call90310 74624
Home›Steel›Tata Tiscon
Steel TMT · Tata Tiscon · in stock

Tata Tiscon 550SD sariya in Muzaffarpur: sizes, weight and today's rate

The short answer

Tata Tiscon 550SD is Tata Steel's super-ductile Fe 550D bar, the one to choose for an engineer-designed frame, a floor you plan to add, or earthquake detailing. We keep it in 6, 8, 10, 12 and 16 mm and order 20 and 25 mm. Tata sells it by the 12 m piece; we show every size per kg, per quintal and per piece, because your engineer's list is in kg.

550
MPa yield, guaranteedTata prints 570, but its own footnote calls that what 95% of tests reach.
16%
Stretch before it breaksAgainst 14.5% that the code asks of a 550D bar.
Ask rate
Per kg todayEvery size, with the date, on the sariya rate page.

One thing to know: Tata's 6 mm is Tiscon 500D, not 550SD. Details below.

What a Tiscon 550SD bar looks like
Anatomy of a Tata Tiscon 550SD bar Side view of the bar with its embossed brand and grade and cross ribs; the cross-section with a hard tempered outer layer and a ductile core; a bundle with the holographic Tag of Trust; and the 12 metre piece length. Side view of one bar TATA TISCON 550SD 12 1 Brand and grade embossed along every bar 2 Cross ribs, rolled in for grip on concrete Cross-section, as Tata describes it 34 Hard outer layertempered martensite Soft, stretchy coreferrite-pearlite Not to scale One bundle TAG OF TRUST holographic 5 Tag on every bundleLook for it at the yard Bundle count is not published by Tata, so we do not state one. One piece 12 m, every piece
Schematic. Cross-section layers are from Tata's brochure (quenching and self-tempering). Brand and grade embossing, and the Tag of Trust, are from Tata's product page and brochure.
Sizes and weight

Weight of every size, per metre and per 12 m piece

Tata's page lists the sizes but no weights. Here they are, with the range a good piece may weigh. Weigh one piece when the truck comes: a light bar is paid for as steel it does not contain.

The sizes we stock, side by side
Tata Tiscon sizes drawn to scale with each otherRound cross-sections of 6, 8, 10, 12 and 16 millimetre bars at the same scale, with standard weight per metre and per 12 metre piece under each. 6 mm0.222 kg/m2.66 kg / piece8 mm0.395 kg/m4.74 kg / piece10 mm0.617 kg/m7.4 kg / piece12 mm0.888 kg/m10.66 kg / piece16 mm1.58 kg/m18.96 kg / piece Tiscon 500D Cross-sections to scale with each other. Standard weight = d² ÷ 162 kg per metre.
Round cross-sections at the same scale, so the 16 mm bar looks as much bigger than the 6 mm as it is: more than seven times the weight per metre.
Sizekg per metre12 m pieceAllowed rangeCommon use
6 mm
Tiscon 500D
0.2222.66 kg2.53–2.80* kgRings (stirrups), mesh, light slabs and pathways
8 mm0.3954.74 kg4.50–4.98 kgRings and chhat mesh
10 mm0.6177.4 kg7.03–7.77 kgChhat, lintel and sunshade bars
12 mm0.88810.66 kg10.34–10.98 kgBeams, columns and chhat main bars
16 mm1.5818.96 kg18.39–19.53 kgColumn main bars, footings and plinth beam

Standard weight per metre = d² ÷ 162. Allowed range for 8 to 16 mm is worked out from Tata's published weight tolerance: ± 5% up to 10 mm, ± 3% for 12 and 16 mm. *6 mm is Tiscon 500D, so the 550SD tolerance may not apply; the figure shown is the same ± 5%. Your engineer's drawing decides which size goes where.

How many kg is my order?

—

Your order

——Standard weight, d² ÷ 162 per metre.
In quintal—1 quintal = 100 kg
Material at today's rateAsk rate
Send this on WhatsApp

The price is filled in from today's rate. Cutting and delivery are charged separately; ask for the amount for your site. Stage-by-stage kg for a whole house: sariya calculator.

What Tata's own sheet says

The figures, and the fine print under them

Every number below is from Tata's 2026 brochure and its 550SD product page. The right-hand column is the code the bar is measured against.

570 or 550? Which number to design with
Yield strength: the code floor and Tata's printed figureA ruler from 540 to 580 MPa. The IS 1786 floor of 550 is marked. Tata prints 570, which is the value 95 percent of its test results reach. The gap is 20 MPa, about 3.6 percent. below 550: failsevery bar must be hereTata typical 20 MPa = 3.6% gap 540550560570580 Ruler starts at 540 MPa, not zero, so the gap is easy to see 550 MPaIS 1786 floor for Fe 550D.Every Tiscon 550SD barmust reach this. 570 MPaTata's printed figure.95% of its tests reachit; not a floor.
Yield is the load at which a bar stops springing back. A 20 MPa gap is about 3.6%. Useful, but small beside the choice of grade.
PropertyTata Tiscon 550SDThe code floor
Strength
Yield strength, min570* MPa550 (IS 1786 Fe 550D)
Yield strength, max660* MPa660 (IS 13920)
Tensile strength, min15% above yield, not below 655 MPa8% above yield, not below 600 MPa
Tensile ÷ yield1.15 to 1.251.08 min (IS 1786); 1.15 to 1.25 (IS 13920)
Stretch
Elongation, min16%14.5%
Elongation at peak load, min5%5%
Chemistry, max
Carbon0.25%0.25%
Sulphur0.035%0.04%
Phosphorus0.035%0.04%
Sulphur + phosphorus0.070%0.075%
Buying
Weight tolerance± 5% up to 10 mm; ± 3% for 12 and 16 mmTata's page shows the IS limits as ± 7% and ± 5%
Length and sale12 m pieces, sold by the piece at Tata's recommended price—

* Tata's own footnote: "95% values are within this limit". So 570 is a typical figure, not a promise on every bar.

570 is not the floor.The guaranteed minimum yield is the code's 550. A brochure, a dealer or a "top 10 brands" list that says "570 minimum" is repeating the asterisk without the footnote.
Tata's own pages differ a little.The brochure prints sulphur and phosphorus at 0.035% each and 0.070% together. The product page prints under 0.04% each and under 0.075% together, which is the code limit. If you need a figure in a contract, use the looser one.
6 mm is a different bar.The brochure's footnote says 6 mm is currently available in Tiscon 500D. The yield, stretch and tolerance above do not describe it. Ask for the 500D sheet if the drawing needs it.

Beside Saluja Gold: Tata Tiscon vs Saluja Gold, row by row.

When the truck comes

Four checks before the bars are unloaded

The bar on your slab should be the bar on the bill. These take ten minutes.

  • 1Read the bar. "TATA TISCON" and "550SD" are embossed along the bar, not printed or painted (see drawing, point 1). A bar without them, or with a different grade, is not what Tata's page describes.
  • 2Find the tag. Every bundle carries a holographic Tag of Trust (point 5). No tag on a bundle, ask why.
  • 3Weigh one piece per size. Use the allowed range in the size table: for 12 mm, 10.34 to 10.98 kg. Pick the piece from the middle of the bundle, not the top.
  • 4Match the bill. Brand, grade (550SD, or 500D for 6 mm) and size on the bill, with the GST bill number. It is your proof if a question comes up later.

Before dhalai: send photos of the sariya and rings on WhatsApp and we'll check them with you. Steel inside a cast slab cannot be changed. More: real or fake Tata Tiscon · weight per metre.

Rate

How Tata prices the bar, and how we show it

Tata sells 550SD by the 12 m piece, at a Recommended Consumer Price shown at its dealers and published district by district. Engineers write steel in kg. So we put the same bar in three units, with the date.

From our sariya rate page. The page says whether GST is in the rate; the GST bill is on every sale. Cutting and delivery are charged separately; ask for the amount for your site (delivery).
Tata Tisconper kgper quintalper 12 m piece
6 mmAsk rateAsk rateAsk rate
8 mmAsk rateAsk rateAsk rate
10 mmAsk rateAsk rateAsk rate
12 mmAsk rateAsk rateAsk rate
16 mmAsk rateAsk rateAsk rate

Piece price to kg price

If a dealer quotes you per piece, divide by the weight of the piece. A 12 mm piece quoted at a price P is P ÷ 10.66 per kg. Do it for 8, 10 and 16 mm with the weights in the table above.

The rate moves with the steel market. What we publish is our rate for the day shown on the page, not a quote that holds next week.

Is it for my house

Where 550SD earns its price, and where it does not

Muzaffarpur is in earthquake zone IV under IS 1893, and Tata's brochure builds its case on exactly that zone. Here is the plain version.

Engineer-designed frame

G+1 and up
  • The drawing often asks for earthquake detailing (IS 13920), which wants the 1.15 to 1.25 tensile-to-yield band Tata's sheet prints.
  • Buy the grade on the drawing and put it on the bill.

Ground floor now, more later

Columns and footings poured today
  • They must carry the floor you add in five years, and steel in cast concrete cannot be changed.
  • Decide before dhalai. 550SD is the safer choice.

Simple single storey

No floor planned
  • A cheaper certified bar is fair here. Detailing counts more: rings with 135° hooks, cover blocks, proper lap.
  • Compare: Tata vs Saluja Gold.

The "6% less steel" claim

From Tata's brochure
  • It comes from a study of frames designed for 550, in zone IV. The saving needs an engineer to design for it.
  • 550 bars in a 500 design give you margin, not a smaller bill. Do not cut sizes yourself.

Earthquake zone and which grade: zone and sariya in Muzaffarpur · Fe 500, 500D, 550D.

Questions people ask us

Short answers

Is Tata Tiscon sariya good? (Tata Tiscon saria kaisa hai)

It is one of the best-documented bars on the market. Tata prints a full sheet: Fe 550D, super-ductile, 16% elongation, a tensile-to-yield ratio of 1.15 to 1.25, sulphur and phosphorus capped at 0.070% together, and "TATA TISCON 550SD" embossed on every bar. Whether it is right for your house depends on the building: for an engineer-designed frame or a floor you plan to add, it is the bar we advise. For a boundary wall or shed, a cheaper certified bar is fair. See Tata Tiscon vs Saluja Gold.

What is the Tata Tiscon rate today in Muzaffarpur?

Our rate for each size is on the sariya rate page, per kg, per quintal and per 12 m piece, with the date. Tata itself sells the bar by the piece at its Recommended Consumer Price, shown at dealers, and publishes it by district. We show our own rate for Muzaffarpur with the day on it, because the rate changes.

Tata sells by the piece. How do I compare that with a per-kg price?

Divide the piece price by the weight of the piece: 4.74 kg for 8 mm, 7.40 kg for 10 mm, 10.66 kg for 12 mm, 18.96 kg for 16 mm (standard weight, d² ÷ 162 per metre × 12). Our rate page does the sum for you, so a Tata price and a per-kg price can be put side by side.

How much does a 12 m, 12 mm Tata Tiscon bar weigh?

Standard weight is 10.66 kg. Tata's published tolerance for 12 and 16 mm is ± 3%, so a good piece weighs between 10.34 and 10.98 kg. Weigh one piece when the truck comes. The size table above has every size.

Is Tiscon 550SD the same as Fe 500D?

No. Fe 500D is the IS 1786 grade with a 500 MPa minimum yield. Tiscon 550SD is Tata's super-ductile Fe 550D bar with a 550 MPa floor. If your drawing says Fe 500D, tell your engineer you are buying 550SD; a stronger bar in a 500 design only adds margin. More on what Fe 500, 500D and 550D mean.

Is 6 mm Tata Tiscon also 550SD?

No. Tata's brochure says 6 mm is currently made as Tiscon 500D, not 550SD. That is fine for rings, but do not expect 550SD figures for it. If you need the 6 mm sheet, ask us on WhatsApp.

How do I know the bar is genuine?

Look for "TATA TISCON" and "550SD" embossed along the bar, and the holographic Tag of Trust on every bundle. Ask for brand, grade and size on the bill, and weigh one piece. More checks: real or fake Tata Tiscon.

Do you cut the bars and deliver to site?

Yes. Cutting and delivery are charged separately from the bar; ask for the amount for your site. See cutting and delivery and delivery areas.

Tata prints 570 MPa. Is that the minimum?

No. Tata's own footnote says 570 is the value 95% of its results are within. The guaranteed floor every bar must meet is the IS 1786 figure of 550. 570 is still a good, typical number, but design with 550.

Can you order Tata's ready-made rings (Superlinks)?

We can order them for you; ask on WhatsApp for the time it takes. Our usual rings are bent from 6 or 8 mm bar. Why rings matter: why rings and stirrups matter.

Abhishek Ranjan
Diploma Civil Engineer, Tashya Ventures

Handles cement and steel at our Reva Road store, Muzaffarpur, where this bar is sold. Every figure here was copied from Tata's own sheets on 12 Nov 2026. Where Tata's pages differ, this page says so and gives the safer figure.

Where the numbers come from

  1. Tata Steel, Tata Tiscon 550SD brochure (2026): mechanical and chemical tables (570* yield with the footnote "95% values are within this limit", 660 max, 655 tensile, 1.15 to 1.25, 16% and 5% elongation, S 0.035, P 0.035, S+P 0.070, C 0.25), quench and self-temper cross-section, sale by 12 m piece at the RCP, Tag of Trust, the "up to 6%" saving and its zone IV study, the 6 mm note.
  2. Tata Steel, Tata Tiscon 550SD product page: weight tolerance ± 5% up to 10 mm and ± 3% for 12 and 16 mm, S and P under 0.04% each and S+P under 0.075%, IS 1786 and IS 13920 columns, embossed brand and grade, GreenPro.
  3. Tata Steel Aashiyana, Tiscon 550SD product page: size range 6 to 32 mm; 6 mm described for light reinforcement and secondary work.
  4. IS 1786:2008 and IS 13920:2016 limits as printed in the code columns of Tata's table. Weight per metre: d² ÷ 162, the standard formula, the same one used in our weight per metre guide.
  5. Zone IV for Muzaffarpur: IS 1893 (Part 1), as used in the Tata brochure's study and in our zone guide.

Send us your bar list

Sizes and pieces, or the kg from your engineer. We'll send back the weight and today's rate, per kg and per piece, on WhatsApp.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR