Coat stops at the floor line
Water runs into the floor-wall joint and through the wall. Take the coat over the gola and at least 1 ft up every wall.
A bathroom gets two waterproof layers: one inside the sunken floor before it is filled, and one just under the tiles. Most leaks into the room below come through the gaps: round a pipe, at the floor trap, or where the floor meets the wall. The flat middle of the floor rarely leaks. Once the tiles are on, all of this is buried, so it has to be right first time.
The makers give different minimums for the walls. Dr. Fixit says 20 cm, Birla White says at least 300 mm and higher in the shower. We go with 1 ft, the higher of the two.
The first layer lines the bare sunken slab and its sides before the filling goes in. The second goes on the sloped screed just under the tiles. Dr. Fixit and Birla White both put the sunk coat on before filling, because once it's filled nobody can get at it.
The joint between floor and wall is where a floor coat most often fails. Carry the coat up over the gola and at least 1 ft up the plaster, behind the WC and basin too.
With a bucket and mug, water splashes to about 4 ft on the tap wall and about 2 ft along the side walls next to it (usual practice). With a shower, take it up to the shower head, about 7 ft, or to the top of the tiles.
Every pipe that passes through the slab or the sunk wall gets its gap packed solid, then the coat is carried a little way up the pipe. The second coat goes down into the neck of the floor trap. Birla White's warranty doesn't cover leaks from the trap or untreated tile joints, which shows how often these spots fail.
Water creeps along the screed and out under the door frame into the next room, so the coat runs across the threshold too (usual practice).
The same idea works for a kitchen: the floor of the washing area and the sink wall up to counter height. Dr. Fixit says a kitchen usually has less standing water, so the treatment can be lighter: kitchen waterproofing.
Thirteen steps in three stages. Red steps are work and blue steps are water tests. The waits come from the UltraTech and Birla White sheets. Where the two differ, we give the longer wait.
At dhalai, mix WP+200 into the concrete at 200 ml per 50 kg bag of cement, in half the mixing water (UltraTech). If the slab is already cast, go to step 2.
at castingChip off loose bits and fill honeycombed patches. Birla White says to fill cracks under 3 mm with a crack filler and repair wider ones with polymer mortar. Wet the slab just before the next step, with no water left standing on it.
same dayRough up the pipe with sandpaper (usual practice). Brush a cement slurry made with Seal & Dry SBR onto the pipe and the concrete. Then pack the gap solid with mortar made with SBR and WP+200, and mix as printed on the SBR pack. Birla White's sheet uses a non-shrink grout with an epoxy seal on top instead. Either way, the gap must be filled solid, not just smeared over.
cure a few daysMake a rounded fillet about 50 × 50 mm (2 in) where the sunk floor meets its walls. Birla White makes it with SBR polymer mortar over an SBR bond coat and keeps it damp for 3–4 days. It also asks for glass-fibre mesh in the first coat over the gola. We can order the mesh for you.
3–4 days dampBlock the outlets and fill 50 mm of water for 48 hours (Birla White). If the ceiling below shows a patch now, fixing the slab is cheap. After the floor is tiled, it isn't.
48 hHi-Flex: two coats, 0.6–0.7 mm each, at least 8 hours apart, the second at right angles to the first (UltraTech). Or Seep Blocker 2K: add 2 parts powder to 1 part liquid, with no water, let it stand 5 minutes, then brush on. Leave 6–8 hours between coats (Birla White). Cover the floor, the sunk walls, the gola and the pipe collars, and carry the coat about a foot up the room walls.
6–8 h · Hi-Flex ≥ 8 hSeep Blocker 2K: let it air-dry for 3–6 hours with no water on it. Then keep it damp for 2–3 days by spraying or with wet sacking, and let it air-dry for 3–4 days before water stands on it (Birla White). Hi-Flex: cure as printed on the pack. Don't apply either above 35 °C surface heat or in the afternoon sun (Birla White).
about a weekAbout 7 days after coating, fill 50 mm of water for 48 hours with the outlets closed (Birla White). Chalk the water level on the wall and check the ceiling below twice a day. Drain it without scratching the coat.
48 hBirla White's sheet: 2–3 mm of Levelplast, or a spatterdash of cement, SBR and coarse sand at 1:1:1.5. After 24–48 hours, add 12–15 mm of 1:4 cement plaster, then cure it 7 days. UltraTech likewise recommends a screed or plaster over Hi-Flex. This layer stops broken brick and the mason's tools from cutting the coat.
7 daysThe usual practice here is broken brick set in a lean cement mortar, packed firmly round the trap and pipes. Don't use loose sand or site rubbish: if water ever gets in, they soak it up and hold it like a sponge.
a few daysLay 1:4 mortar with WP+200, falling towards the floor trap. Set the top of the trap so the finished tiles run down into it. A fall of about ½ inch over 4 ft (1 in 100) is usual practice. If drain pipes run on the floor, Birla White wants the screed at least 20 mm thick over them.
keep dampOn the dry screed, into the neck of the floor trap, 1 ft up every wall, and up the wall you bathe at. While the second coat is still wet, throw dry coarse sand onto it so the tile adhesive has something to grip (usual practice). Water-test the floor once more, overnight or for a day (usual practice).
cure, then testFix the tiles with TileStix Intero Grip+ (TX2), which Birla White rates for ceramic tiles up to 450 × 450 mm indoors. That covers our 300 × 300 floor and 300 × 450 wall tiles. Fill the joints with TileLynk, and seal the joint round the trap and every pipe outlet. You can walk on the tiles after 24 hours (Birla White). Never put putty under tiles.
walk after 24 hWhich tile won't slip: bathroom floor tiles. Laying them level and tight: how tiles are laid. Want us to check the work? Send photos on WhatsApp before the sunk is filled and before the tiles go on, and we will look at them with you.
This counts from a cured slab with the plumbing done. Most of the time goes on curing and water tests, not on work. A thekedar who promises the bathroom in three days is skipping the curing and the tests.
| Stage | Wait |
|---|---|
| Gola, kept dampBirla White sheet | 3–4 days |
| Water test, bare slab50 mm of water (Birla White) | 48 h |
| Coat 1 to coat 2Seep Blocker 2K: 6–8 h (Birla White sheet; its blog says 5–6 h) · Hi-Flex: at least 8 h (UltraTech) | 6–8 h |
| Curing the coatSeep Blocker 2K: 2–3 days damp, then 3–4 days dry | ~7 days |
| Water test, coated sunk50 mm of water (Birla White) | 48 h |
| Protection plaster cureBirla White: mist spray 3 times a day | 7 days |
| Filling, screed, second coatUsual practice; coat cured as per its pack | 4–6 days |
| Tiles to walkingTileStix TX2 (Birla White) | 24 h |
| From bare sunk to first bath | ~4 weeks |
Each picture shows the fault on the left (red marks the mistake) and what you see months later on the right. Dr. Fixit's FAQ makes the same point: a good product is usually let down by how it was applied.
Water runs into the floor-wall joint and through the wall. Take the coat over the gola and at least 1 ft up every wall.
The commonest bathroom leak. Pack the gap solid with SBR mortar, then carry the coat up the pipe. This is step 3.
Sharp brick and a mason's tools cut a bare coat. Birla White puts a 12–15 mm protection plaster over the coat first. This is step 9.
Standing water finds every weak joint. Slope the screed down to the trap and set the trap's top below the tiles. This is step 11.
Forty-eight hours of water costs nothing. Finding the leak after tiling costs the whole floor. These are steps 5 and 8.
Even waterproof putty does not stop an active leak. Stop the water in the bathroom first, let the wall dry fully, then waterproof putty, primer and paint.
Birla White's post on old bathrooms coats the existing walls and floor with Seep Blocker 2K without a full renovation. It doesn't say when that isn't enough. Dr. Fixit warns that re-grouting alone rarely stops an existing leak. Here is how we tell the cases apart. For the full repair guide, see bathroom water reaching the room below.
Don't use the bathroom for two days, but leave the water supply on. Mark the edge of the stain below with a pencil.
Stain still growing: a supply pipe is leaking under pressure. That's a plumber's job, not a coating: leaking pipe joint.
Stain drying: the water comes from use, through the joints, the trap or the floor. Read on.
Put in your bathroom's size. Coat areas include the sunk sides, 1 ft up every wall and the wall you bathe at, for both layers. Coverage comes from the makers' sheets, read the safe way.
Prices are filled in from today's rate. Tiles, TileStix and TileLynk: tile calculator. Roof, tank or any other job: waterproofing calculator. Glass-fibre mesh or non-shrink grout: we can order it for you; ask on WhatsApp how long it takes.
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
UltraTech Weather Pro Hi-FlexTwo-part flexible coat, stretches up to 100% · 12, 24 kg₹ 2,032per 12 kg Birla White Seep Blocker 2KPowder + liquid, 3-year warranty on 12 kg+ · 3 kg (15 kg: we order it)₹ 358per 3 kgHi-Flex or Seep Blocker 2K? Both do the job. Hi-Flex covers more per kg and comes in bigger packs, so it suits a whole new bathroom. Seep Blocker 2K comes in a small 3 kg pack, good for a repair. It needs 12 kg on one surface for the Birla White warranty. The full comparison: Hi-Flex vs Seep Blocker 2K. Today's price for every pack: waterproofing rates · tile rates.
No single product does the whole job. A flexible coating does most of the work: Hi-Flex or Seep Blocker 2K, two coats in the sunk and two under the tiles. WP+200 goes into the concrete and screed at 200 ml per 50 kg bag, and Seal & Dry SBR goes into the mortar for the gola and pipe sleeves. How carefully the work is done matters more than the brand.
The whole floor, twice. At least 1 ft up every wall: Dr. Fixit says 20 cm, Birla White at least 300 mm, and we use the higher figure. The wall you bathe at goes to about 4 ft with a bucket, or to the shower head with a shower. Every pipe through the floor, the floor trap, and the strip under the door frame need it too.
Plumbing finished and tested first. Then pack every pipe sleeve with SBR mortar, make a rounded gola in every corner, and water-test the bare slab for 48 hours. Apply two coats of Hi-Flex or Seep Blocker 2K over the floor and sides, cure them, and water-test again with 50 mm of water for 48 hours. Protect the coat with a thin plaster before filling. Steps 1 to 9 above.
About four weeks from a bare sunk to the first bath, done by the makers' sheets. Curing, two 48-hour water tests and a 7-day cure of the protection plaster take most of that. You can walk on the tiles 24 hours after laying them with TileStix.
No. WP+200 makes the concrete itself resist water, but bathroom leaks come through the gaps: round pipes, at the trap, at the floor-wall joint and through cracks. UltraTech's own brochure puts bathrooms among the places that need a coating on top as well.
Sometimes. If water gets in only at open joints and round the trap, re-grouting with TileLynk and resetting the trap in SBR mortar can stop it. Dr. Fixit warns that re-grouting alone is unlikely to stop an existing leak, so check the ceiling below again after two weeks. If the stain stays, the floor sounds hollow or a pipe in the sunk is broken, the floor has to come up. Start with the 2-day test above.
Yes, with the same products. Dr. Fixit notes that a kitchen usually has less standing water, so the treatment can be lighter. Corners, pipe openings and the sink wall up to counter height still need the coat. See kitchen waterproofing.
We don't do site visits. Send us photos on WhatsApp at two points: before the sunk is filled (with the coat and the water test showing), and before the tiles go on. We'll look at them with you and say what we see.
Paint Engineer at our Reva Road store, Muzaffarpur, where he handles paint, putty, tiles and waterproofing. Every figure on this page was checked against the maker's own sheet on 12 Nov 2026. Where the makers disagree, the page says so and gives the safer figure. Where a figure is local practice rather than a maker's, the page says "usual practice".
Length, width and sunk depth. We'll send back the coating, WP+200, SBR and cement for it, with today's price, on WhatsApp.