हिंदी Call90310 74624
Home›Wires›1.5 sq mm
Wires · V-Guard Classo+ · in stock

1.5 sq mm wire in Muzaffarpur: lights, fans and 6 A sockets, 13 A in a pipe, 90 m coil

The short answer

Use 1.5 sq mm for lights, fans and 6 A sockets, and nothing heavier. V-Guard Classo+ 1.5 sq mm carries 13 A in a wall pipe (16 A clipped in open air), so it takes a 10 A MCB. Keep the geyser, AC, motor and kitchen line off it: those go on 2.5 sq mm with a 16 A MCB, or 4 sq mm.

13 A
in a wall pipe16 A clipped in the open (V-Guard).
10 A
MCB in frontPlan up to 2,300 W on the circuit.
90 m
one coilRed and black on the shelf; green we order.
Ask rateClasso+ 1.5 sq mm, 90 m coil, with GST. Per metre: coil price ÷ 90.
Today's price on the wire price list
One ruler: where 1.5 sq mm stops
Wire amps and MCB on one rulerA ruler from 0 to 26 amps. The MCB trips at 10 A, the wire carries 13 A in a wall pipe and 16 A clipped in the open.02468101214161820222426Asafe load10 A MCBtrips here13 Awire limit in a wall pipe16 Aclipped, open air
The 10 A MCB trips before the wire reaches its 13 A pipe limit. That gap is the safety. A bigger MCB removes it.
What it feeds

Put it on these, keep it off those

Put 1.5 sq mm on

Light and fan circuits

  • Every light and ceiling-fan point, from its board.
  • 6 A sockets: TV, phone charger, table fan, the thin-pin plug.
  • The loop from room to room on the light circuit, with a 10 A MCB.
  • Earth wire for these circuits, in green, the same 1.5 sq mm.
Most houses use two 1.5 sq mm circuits per floor: lights and fans, and 6 A sockets.
Keep it off

Anything that draws more

  • 16 A sockets, the kitchen line, the geyser: 2.5 sq mm, 16 A MCB.
  • Split AC: name plate up to 12 A takes 2.5 sq mm; 12 to 16 A takes 4 sq mm: wire for an AC.
  • Water pump or any motor: its own line, sized from the name plate.
  • Never a 16 A MCB on 1.5 sq mm to stop it tripping. Find the load instead: MCB tripping again and again.
Wrong-size wire does not fail on day one. It fails in May, on the busiest evening.

Which size for every point in a house, side by side: 1.5 vs 2.5 sq mm wire.

Amps and MCB

The numbers for 1.5 sq mm Classo+

V-Guard prints a current figure for Classo+; most wire makers' pages print none. The full chart for every size is the wire amps chart.

WhatFigureWhat it means
In a wall pipe13 AThe figure to use in a house; about 2,990 W at 230 V.
Clipped, open air16 ANot for a house: even the bit near the board counts as in-pipe.
MCB in front10 APlan the load up to 2,300 W. The 10 A SP B-curve Elegna is in stock.
Strands × mm, overall width30 × 0.25 · 2.8 mmSoft multi-strand, so it bends round a pipe elbow and pulls through a long run.
Max resistance13.3 Ω/kmThe number to hold the wire to; insulation is 0.6 mm.
Copper in a 90 m coil~1.2 kgOur own sum from the size, so the price follows copper.
Why the MCB is smaller than the wire's ampsThe MCB is there to protect the wire. It is picked from the wire's in-pipe amps (13 A), one standard step down (10 A), and the load must fit under it. The same wire carries less in a pipe because the heat cannot leave. Rule and worked examples: wire amps chart; room by room: which MCB for which load.
How many coils

1.5 sq mm coils for your house

Wire is bought in sets of three coils of one size: red for phase, black for neutral, green for earth. One set of 1.5 sq mm is 270 m of wire but only about 90 m of circuit.

House (single floor unless stated)1.5 sq mm coilsWire used
1 room, kitchen, bath3~211 m
2 rooms, kitchen, bath, AC, geyser, pump3~281 m
3 rooms, kitchen, 2 baths, AC, geyser, pump6~380 m
Two floors, 2 rooms each6~535 m
Three floors, 2 rooms each12~911 m

Usual practice with 10% spare, from our coil guide; your electrician's point list decides the final count. Counter: wiring calculator. Pipe for these runs is 20 mm: conduit pipes.

Our shelf

1.5 sq mm at our store, with today's price

Every coil goes out on a GST bill. Green coils, other makes and any other size we can order for you; ask on WhatsApp for the time it takes. All sizes in one place: wire price list. Delivery is charged separately; ask for the amount for your site (delivery).

Why sites differ

Search it and you get different answers

We read what sites say about 1.5 sq mm on 18 Nov 2026. Here is the spread, and the figure we stand by.

SourceAmpsPriceGap
NoBroker forum6 AnoneSays 6 A; no MCB, no pipe or clip.
Moglix, KEI Homecab14 A₹3,129No MCB advice, no note on pipe.
Moglix, PNSnone₹1,508No amps at all; strand count and standard missing.
Tashya (V-Guard Classo+)13 A pipe · 16 A clipAsk rateMCB, circuits, coils and colours on one page.
Compare like with likeThe two online prices are for different makes and were listed well below a printed MRP, so the gap between them says little. Ask for the make, the 90 m length, the metre marks and a GST bill. Then compare the price.
Questions people ask us

Short answers

What is the 1.5 sq mm wire price in Muzaffarpur?

Today's price for a 90 m coil of Classo+ 1.5 sq mm, with GST, is on the wire price list, updated each morning. Divide by 90 for the price per metre. We sell whole 90 m coils, red and black from the shelf; green we order.

How many amps does 1.5 sq mm wire carry?

V-Guard's Classo+ table: 13 A in a wall pipe, 16 A clipped in the open. Almost every wire in a Bihar house runs in a pipe, so use 13 A, and put a 10 A MCB in front of it.

Can I run a geyser or AC on 1.5 sq mm?

No. A geyser goes on 2.5 sq mm with a 16 A double-pole MCB; an AC goes on 2.5 sq mm (name plate up to 12 A) or 4 sq mm (12 to 16 A). On 1.5 sq mm a 10 A MCB would trip at once, and a bigger MCB would let the wire get hot inside the wall. See 2.5 sq mm and wire for an AC.

Is 1.5 sq mm enough for both a 6 A and a 16 A socket?

For a 6 A socket (TV, charger, table fan) yes. A 16 A socket (the thick-pin plug for a mixer, iron, geyser or cooler) needs 2.5 sq mm and a 16 A MCB.

Why do some websites say 6 A or 14 A?

Makers and sites use different test conditions, and some pages repeat a rule of thumb. We use V-Guard's own 13 A in a pipe because it is the lower of the maker's two figures and matches how the wire is really laid.

Is a 90 m coil really 90 metres?

Check it at the counter: read the metre mark printed on the wire near each end and subtract. How: Classo+ coil and how to check it. As a second check, the copper alone in a 1.5 sq mm coil weighs about 1.2 kg; a coil that feels far lighter is short or thin.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wires, switchgear, inverters and pumps at our Rewa Road store, Muzaffarpur. The amp figures are V-Guard's own, checked on 18 Nov 2026. Where makers disagree, this page says so and takes the safer figure.

Where the numbers come from

  1. V-Guard, Classo+ triple layer insulation wire: 13 A in a wall pipe and 16 A clipped for 1.5 sq mm, 30 × 0.25 mm strands, 2.8 mm overall, 0.6 mm insulation, 13.3 Ω/km, 70 °C, 1100 V.
  2. MCB at or below the in-pipe figure, earth the same size as phase (IS 732), coil counts and pipe lengths: our own wire amps chart and coil guide, linked above.
  3. Other sites read on 18 Nov 2026: NoBroker, Moglix (KEI), Moglix (PNS).
  4. Store facts: our own shelf at Rewa Road; colours as on our last supplier bill.

Tell us your points, we'll tell you the coils

Send the number of lights, fans and sockets. We reply with the coils by size and colour, and one price for the lot.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com