हिंदी Call90310 74624
Home›Wires›Classo+
Wires · V-Guard · in stock

V-Guard Classo+ wire in Muzaffarpur: five sizes, seven colours, 90 m coil and today's price

The short answer

Classo+ is V-Guard's own everyday house wire. Soft multi-strand copper in flame-retardant PVC, rated 70 °C and 1100 V, sold in a 90 m coil. It is made in five sizes, 0.75 to 4 sq mm. We keep 0.75, 1, 1.5 and 2.5 sq mm on the shelf and order 4 sq mm and any other colour for you. Today's price for each is on the wire price list, with GST on the bill.

99.97%
copperV-Guard's figure, with 102% IACS conductivity.
70 °C
up to 1100 VFlame retardant. No low-smoke claim.
4 sq mm
largest sizeClasso+ stops here. 6 sq mm is Ultravolt.

Which size for which wire in the house, and the MCB for each: wire amps chart.

One coil
A Classo+ 90 m coilA coil of red house wire with a yellow band reading 90 m ASSURED, and seven colour dots: red, yellow, blue, black, green, grey, white. 90 m90 mASSUREDthe "90 m ASSURED" seal on the coilRedYellowBlueBlackGreenGreyWhiteseven colours, 0.75 to 4 sq mm
A Classo+ coil: 90 metres, one colour, and V-Guard's "90 m ASSURED" seal. Seven colours are made; on our shelf the 0.75, 1, 1.5 and 2.5 sq mm coils are green, red and black, red and black, and black.
Sizes

Five sizes, drawn to one scale

Each size is the same wire built thicker: more strands, a thicker bundle of copper, a little more insulation. These are V-Guard's own table figures.

Cut ends, as V-Guard's table gives them
Cut ends of the five Classo+ sizes, drawn to one scaleCross-sections of 0.75, 1, 1.5, 2.5 and 4 sq mm Classo+ wire. Strand counts: 24, 32, 30, 48 and 56. Overall diameter 2.3, 2.5, 2.8, 3.4 and 4.0 mm. Each has copper strands inside three layers of insulation. 0.7524 × 0.2Ø 2.3132 × 0.2Ø 2.51.530 × 0.25Ø 2.82.548 × 0.25Ø 3.4456 × 0.3Ø 4.01 mm
Strand counts and diameters are V-Guard's. Strands are drawn a little smaller than true so you can count them, and the three insulation layers are shown as a schematic split; V-Guard gives only the total thickness. Under each: strands × strand diameter in mm, and the overall diameter.
Size, sq mmStrands × mmOverall Ø, mmInsulation, mmMax resistance, Ω/kmCopper in 90 m, kgOn our shelf
0.7524 × 0.22.30.6260.60green
132 × 0.22.50.619.50.81red and black
1.530 × 0.252.80.613.31.21red and black
2.548 × 0.253.40.77.982.02black
456 × 0.34.00.84.953.23we order it

Strands, diameter, insulation and resistance: V-Guard's Classo+ table. Copper weight is our own sum: nominal area × 90 m × 8.96 g per cm³, so a coil is mostly copper by weight and its price follows the copper market (why the price moves).

Many fine strands, not one thick coreA 1.5 sq mm Classo+ has 30 strands of 0.25 mm. That is why it bends round a pipe elbow and pulls through a long run with three or four wires in it. A single-strand wire of the same size is stiff and kinks at the bend.
Amps and MCB are on their own pageHow much each size carries in a wall pipe, and the MCB in front of it, are on the wire amps chart; for an AC, which wire for your AC. One rule to carry with you: 2.5 sq mm gets a 16 A MCB, never 20 A.
What is inside

What V-Guard says is in the wire

These are claims from V-Guard's Classo+ page. We say which ones it backs with a number and which it does not.

1The copper

99.97% pure copper with 102% IACS conductivity. IACS compares a conductor with the old reference grade of annealed copper, so 102% is what good pure copper reads. The table prints a maximum resistance for every size, which is the number to hold it to.

2The insulation

FR PVC in three layers. V-Guard also claims "anti-termite" insulation and a "moisture guard" that keeps the copper from darkening. It names no test for either, so treat them as the maker's claim, not a certificate.

3Fire and heat

Flame retardant, 70 °C, up to 1100 V. A flame does not run along the wire. It is not sold as low-smoke, and 70 °C is the ordinary rating. For hotter lines or low smoke, Ultravolt's other ranges are the step up: Classo+ vs Ultravolt.

What the Classo+ product page leaves out: a warranty period (it says only "terms and conditions apply") and the IS number. The number is on V-Guard's quality page: IS 694:2010, licences CM/L-0006205957 (Coimbatore) and CM/L-0009707087 (Kashipur). Read the print along your own coil and check its number in the BIS Care app. More: IS 694 and the ISI mark.

Coil and colours

The 90 m coil, and how to check it

Check the length yourself
Reading the metre marks at the two ends of a coilA red wire with printed metre marks: 0412 m at one end and 0502 m at the other. 502 minus 412 is 90 metres. Example numbers. 0412 m 0502 m 0502 − 0412 = 90
Example numbers. Read the metre mark near each end of the coil and subtract; it should come to 90.

V-Guard's "90 m ASSURED" seal is its promise that the coil holds 90 metres. It costs nothing to check: read the metre mark printed along the wire near one end, then near the other, and subtract. If a coil is short, say so at the counter before the seal is cut.

A house needs several coils of each size, one for each colour of each circuit: how many coils a house needs. Whole-house lists get one price for the lot on the price list.

Seven colours

Red on shelfYellowBlueBlack on shelfGreen on shelfGreyWhite

In a single-phase house the usual practice is red for phase, black for neutral and green for earth, with the same size for all three: wire colours. Yellow and blue come into use with a three-phase supply. Colours with a green outline are on our shelf today; every other colour we order for you.

Our shelf

Classo+ at our store, with today's price

Every coil goes out on a GST bill. The 4 sq mm coil, other colours and any other size we can order for you; ask on WhatsApp for the time it takes. Today's price for every coil: wire price list. Delivery is charged separately; ask for the amount for your site (delivery).

The other wire we sell

Classo+ or Ultravolt?

UltraTech's new house wire is spelt Ultravolt by its maker, with a V; most people say UltraBolt. We sell both.

Take Classo+ when

  • you want the wire electricians here already know, and a soft strand that pulls easily
  • you want it from the shelf today, in 0.75 to 2.5 sq mm

Look at Ultravolt when

  • the line is an AC, geyser or kitchen, or you want low smoke
  • you need 6 sq mm, which Classo+ does not come in
  • you want it on the same bill as your UltraTech cement

Classo+ stays on our shelf; Ultravolt sits beside it. The point-by-point is on Classo+ vs Ultravolt, and the wire itself is on the Ultravolt (UltraBolt) page.

Questions people ask us

Short answers

What is the V-Guard Classo+ wire price in Muzaffarpur?

Our price for every size is on the wire price list, per 90 m coil with GST, updated each morning. Divide by 90 for the price per metre. Prices differ between shops and move with copper, so we do not quote one from memory.

How many amps does Classo+ carry, and which MCB goes with it?

It depends on the size and on whether the wire runs in a pipe. V-Guard's figures, with the MCB for each size, are on one table: the wire amps chart. Whatever the size, the MCB must be at or below what the wire carries.

Does Classo+ come above 4 sq mm?

No. V-Guard's table for Classo+ ends at 4 sq mm. For a 6 sq mm main line from the meter we supply Ultravolt SafePlus, which we order for you.

Is Classo+ ISI marked?

V-Guard's quality page says its PVC cables are BIS-certified under IS 694:2010, with licences CM/L-0006205957 (Coimbatore) and CM/L-0009707087 (Kashipur). The Classo+ product page prints no number, so read the mark and licence number on your own coil and check it in the BIS Care app. How to read the print.

Does Classo+ come with a warranty?

V-Guard's product page gives no warranty period; it says only that terms and conditions apply. Keep the GST bill and the coil label.

Is a Classo+ coil really 90 metres?

V-Guard puts a "90 m ASSURED" seal on the coil. To check, read the metre marks at the two ends and subtract.

Who makes Classo+? Is it a private label?

It is V-Guard's own wire, made by V-Guard Industries at its wires and cables plants. It is not a shop's private label.

Which colour should I take?

Single-phase house wiring uses red for phase, black for neutral and green for earth, all of the same size. Yellow and blue come in with a three-phase supply. Count coils by colour: wire coils for a house.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur. The figures here are V-Guard's own, checked on 13 Nov 2026. Where V-Guard's pages say nothing, this page says so.

Where the numbers come from

  1. V-Guard, Classo+ triple layer insulation wire: 99.97% copper, 102% IACS, FR PVC with three layers, anti-termite and moisture-guard claims, 70 °C, up to 1100 V, 90 m ASSURED, seven colours, and the size table (strands, resistance, diameter, insulation, current).
  2. V-Guard, Quality assurance: PVC insulated cables BIS-certified under IS 694:2010; licences CM/L-0006205957 (Coimbatore) and CM/L-0009707087 (Kashipur).
  3. Copper weight per coil: our calculation from the nominal area, 90 m and 8.96 g per cm³.
  4. Store facts: our own shelf at Rewa Road; sizes and colours as on our last supplier bill.

Tell us your points, we'll tell you the coils

Send the number of lights, fans, sockets and ACs. We reply with the coils by size and colour, and one price for the lot.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com