Ordinary house, normal budget
- Same copper, same 70 °C, same coil. Pick by price per coil on the day.
- If your electrician pulls long runs with many bends, Classo+ is softer to pull.
- If smoke safety matters to you, SafePlus.
For ordinary house wiring they are equals. Classo+ and Ultravolt's matching range, SafePlus, both use 99.97% copper, both are rated 70 °C and 1100 V, both come in 90 m coils. Buy whichever costs less per coil on the day.
The real differences are smaller: SafePlus gives off less smoke in a fire. Classo+ has three layers of insulation, finer strands that pull easily through pipe, and a 90 m assured seal. For kitchen, geyser and AC lines, Ultravolt's GreenCore (95 °C) is the step up.
Ultravolt makes three house-wire ranges. SafePlus is the one to put against Classo+; GreenCore and NextGen are higher grades. Every figure is from the maker's own page or data sheet.
| What | V-Guard Classo+on our shelf | Ultravolt SafePluslike for like | Ultravolt GreenCoreheat resistant | Ultravolt NextGentop grade |
|---|---|---|---|---|
| Copper | 99.97%, 102% IACS | 99.97%, bare annealed | 99.97%, bare annealed | 99.97% |
| Insulation | FR PVC, three layersflame retardant, anti-termite | FR-LSH LF PVCflame retardant, low smoke, low halogen, lead-free | HR FR LF PVCheat resistant, flame retardant, lead-free | HFFR, E-beam cross-linkedhalogen-free, flame retardant, low smoke |
| Heat rating | 70 °C | 70 °C | 95 °C | 125 °C |
| Voltage grade | Up to 1100 V | 1100 V | 1100 V | 1100 V |
| Strands, 1.5 sq mm | 30 × 0.25 mmfully bunched, "extra flexible" | 22 × 0.30 mmClass 2 in 1, 1.5, 2.5 sq mm | 30 × 0.25 mmClass 5, fine flexible | 30 × 0.25 mmClass 5 |
| Resistance, 1.5 sq mm | 13.3 Ω/km | 12.1 Ω/km | 13.3 Ω/km | 13.3 Ω/km |
| Amps in pipe, 2.5 sq mm | 18 A | 20 A | 24 A | 32 A |
| Coil | 90 m, "90 m ASSURED" seal | 90 m | 90 m and 180 m | 90 m |
| Colours | 7: red, yellow, blue, black, green, grey, white | 6: red, yellow, blue, black, green, white (no grey) | ||
| Sizes | 0.75 to 4 sq mm on V-Guard's table | 0.75, 1, 1.5, 2.5, 4 and 6 sq mm in all three | ||
| ISI licence | IS 694:2010CM/L-0006205957, CM/L-0009707087 | IS 694CM/L 7100158506 | IS 694CM/L 7100158506 | IS 17048CM/L 7100158405 |
| Warranty | None published | None published | None publishedclaims 40+ years of life | None publishedclaims 80+ years of life |
| Maker | V-Guard Industries | UltraTech Cement Ltd, wires and cables unit (Aditya Birla Group), plant at Bharuch, Gujarat | ||
| Price, 90 m coil | Ask rate | Ask rate | Ask rate | Ask rate |
On a phone, slide the table sideways. Shaded rows are the same for both brands. Today's coil prices for every size: wire price list.
Copper purity is a tie, so stop comparing it. These are the points where the two brands really part ways.
Every wire here is flame retardant: it will not carry a flame along the wall. The difference is smoke. SafePlus and NextGen are made to give off less smoke and less harmful gas, which keeps a staircase visible long enough to get out. Classo+ and GreenCore make no low-smoke claim.
Wire in a pipe inside a brick wall has no air around it, and a Muzaffarpur roof slab holds heat all evening. GreenCore is rated 95 °C and NextGen 125 °C, against 70 °C for Classo+ and SafePlus. More headroom means the insulation ages slower on a loaded line.
Classo+ uses 30 fine strands in 1.5 sq mm, so it is soft and slides through a long pipe with bends. SafePlus uses 22 thicker strands: a little stiffer, but about 9% lower resistance (12.1 against 13.3 Ω/km). On a 20 m light circuit that saves about half a volt. Real, but small.
Both sell 90 m coils. Classo+ carries a "90 m ASSURED" seal; GreenCore also comes in 180 m for a whole-house job. Classo+ has seven colours including grey; Ultravolt has six. For red phase, black neutral and green earth, both are enough.
Ultravolt prints its IS standard and BIS licence number (CM/L) on each range's sheet, so you can check it in the BIS Care app before buying. V-Guard's quality page prints IS 694:2010 with licences CM/L-0006205957 and CM/L-0009707087; its Classo+ product page prints no number, so read the ISI mark and licence number on your own coil. Neither brand prints a warranty period for wire.
V-Guard has sold house wire for years and electricians here know how Classo+ handles. Ultravolt is new in 2026. Its sheets are detailed and its figures are tested to Indian standards, but there are no old houses wired with it yet. That is not a fault, only a fact to weigh.
Ultravolt's sheets show more amps per size than Classo+. Part of that is the hotter rating, and part is a different way of working it out. Your circuit does not change: the size and MCB stay the same for every brand.
| Size | Classo+ | SafePlus | GreenCore | NextGen | MCB |
|---|---|---|---|---|---|
| 0.75 sq mm | 6 A | 7 A | 8 A | 13 A | 6 A |
| 1 sq mm | 11 A | 12 A | 14 A | 21 A | 10 A |
| 1.5 sq mm | 13 A | 15 A | 18 A | 24 A | 10 A |
| 2.5 sq mm | 18 A | 20 A | 24 A | 32 A | 16 A |
| 4 sq mm | 24 A | 26 A | 31 A | 41 A | 20 A |
| 6 sq mm | not listed | 31 A | 42 A | 53 A | 25 A |
Two wires, single phase, in a wall pipe, as each maker gives it. The MCB column is ours: a rating at or below the lowest figure in the row, so the wire never heats before the MCB trips. For 6 sq mm we go by Ultravolt SafePlus, the only 70 °C figure.
Start with who you are and what the wire is for. Price comes after, and only between wires that pass the same test.
Is one replacing the other at our store? No. Classo+ stays on our shelf. Ultravolt sits beside it as an order item, and any range, size or colour we don't have on the day we order for you. Ask on WhatsApp for the time it takes. All brands on one page: wire brands compared.
Brand, size in sq mm, 1100 V, the insulation type (FR, FR-LSH, HR FR, HFFR), the IS number and the ISI mark should repeat along the wire. If the size is not printed, don't buy it.
Type the CM/L number from the coil into the BIS Care app. For Ultravolt SafePlus and GreenCore it should read 7100158506; for NextGen 7100158405. The same check works for V-Guard: its licences are CM/L-0006205957 and CM/L-0009707087.
Metre marks are printed along the wire. Read the number at the outside end and at the inside end; the difference should be 90. Ask us to open a coil if you want to see it.
Strip 2 cm. The copper should be bright, not dull or pinkish-grey. Count the strands against the table above. Bend it back and forth: the insulation should not crack. More: asli ya nakli wire.
Wire already in your wall? Send a clear photo of the print on the wire to us on WhatsApp. We'll tell you the brand, size and type, and whether it suits the load you want to add. What the letters mean: FR, FRLS, HFFR wire.
Compare price per coil only between the same size and the same length. A 180 m GreenCore coil is two 90 m coils' worth.
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
Classo+ 0.75 sq mmGreen · 90 m · bell, indicator, small loads₹ 1,056per coil Classo+ 1 sq mmRed · 90 m · light points₹ 1,358per coil Classo+ 1.5 sq mmRed · 90 m · lights and fans, 10 A MCB₹ 1,992per coil Classo+ 2.5 sq mmBlack · 90 m · sockets, 16 A MCB₹ 3,211per coilOther sizes and colours of either brand can be ordered; ask on WhatsApp for the time it takes. Today's price for every coil: wire price list. Full product pages: Classo+ · Ultravolt (UltraBolt).
Yes. UltraTech's wire is spelt Ultravolt, with a V; most people say UltraBolt. It is made by the wires and cables unit of UltraTech Cement Ltd, part of the Aditya Birla Group, at a plant in Bharuch, Gujarat. More: UltraBolt kya hai.
For ordinary house wiring, Classo+ and Ultravolt SafePlus are equals: 99.97% copper, 70 °C, 1100 V, 90 m. SafePlus adds low smoke and a printed ISI licence number; Classo+ has three insulation layers, softer strands and a seventh colour. For heavy lines, GreenCore (95 °C) beats both.
No. Keep 1.5 sq mm on a 10 A MCB for lights and fans, 2.5 sq mm on 16 A for sockets, 4 sq mm on 20 A for an AC that draws 12 to 16 A, whatever the brand. The extra amps are headroom against heat. Switches and sockets have their own 6 A or 16 A limit.
Neither maker prints a warranty period on its wire pages. Ultravolt claims 40+ years of life for GreenCore and 80+ for NextGen; that is a life claim, not a written warranty. Keep the GST bill and the coil label.
V-Guard's quality page says its PVC cables are BIS-certified under IS 694:2010, licences CM/L-0006205957 and CM/L-0009707087. The Classo+ product page prints no number, so read the ISI mark and CM/L number on your own coil and check it in the BIS Care app. Ultravolt prints IS 694, CM/L 7100158506, for SafePlus and GreenCore, and IS 17048 for NextGen.
Both sell 90 m coils; GreenCore also comes in 180 m. Classo+ carries a 90 m ASSURED seal. On any coil, read the metre marks at both ends and subtract.
Yes, as long as each circuit uses the right size and every joint is inside a box. Many houses use a heat-resistant wire on the AC and geyser lines and a normal one for lights. Keep red for phase, black for neutral and green for earth in both brands.
Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur. Every figure on this page was checked against V-Guard's Classo+ page and Ultravolt's own data sheets on 12 Nov 2026. Where the two makers' numbers differ, the page uses the safer one.