Where is the water coming from? Roof, wall, pipe, bathroom or ground, in six tests

The short answer

Buy nothing and break nothing until you know where the water gets in. A wet patch shows where water comes out, not where it enters. Six free tests find the source, and the source decides who fixes it:

  • Rain, a bathroom floor or the ground waterproofing applicator
  • A pipe, a tap fitting, a floor trap or a drain plumber
  • Damp air in closed rooms you: air and sun
1 night
Tank testTaps shut, pump off. If the level falls by dawn, a supply pipe leaks.
50 mm
Pond testWater held on the bathroom floor, trap plugged, for 24–48 h.
2–3 ft
Ground dampA level band no higher than this on a ground-floor wall.
Ask in this order
Decision chart: where is the water coming from Five questions in order. One: does it get worse within a day of rain? Yes means rain water, from the roof or the outside wall. Two: with taps shut and the pump off, does the tank level fall by morning? Yes means a supply pipe, call a plumber. Three: is the patch below or beside a bathroom or kitchen? Yes means do the pond test: floor leaks go to a waterproofing applicator, trap leaks to a plumber. Four: is it a level band at the foot of a ground-floor wall, 2 to 3 feet high, with white salt? Yes means damp rising from the ground. Five: is a square of foil taped on for 24 to 48 hours wet on the room side? Yes means damp air. If none fits, or two do, send photos on WhatsApp. Pencil the patch's edge with today's date, then ask: YESYESYESYESYES NONONONONO 1 2 3 4 5 Gets worse within aday of rain, shrinksin dry weeks? Taps shut, pump off:tank level falls bymorning? Patch below or besidea bathroom orkitchen? Level band at the footof a ground-floor wall,2–3 ft, white salt? Foil taped on for24–48 h: wet on theroom side? test 1test 2test 3test 4test 6 RAIN WATERSUPPLY PIPEPOND TESTGROUND DAMPDAMP AIR Top-floor ceiling:the roofOuter wall: test 5 a joint or pipein the wallPlumber Floor fails:applicatorTrap fails: plumber rising from belownot a pipeApplicator condensationair and sun,no chemical None fits, or two do? Send a photo of the patch and of the floor above it.
waterproofing applicatorplumberyou
A house can have two sources at once. If a "yes" fixes only part of the patch, carry on down the chart.
Before the tests

Six one-minute looks that find the cheap leaks

Half the patches we are shown come from one of these. Each one costs almost nothing to fix, so look before you test.

Tank overflow pipeDoes it end against the wall or drip down the outside? A stuck float valve fills the tank till it spills. Turn the pipe away from the wall. Tank leaking at its base: water tank.
AC drain pipeWhere does the indoor unit's drain end? On a wall or a chhajja it soaks the plaster all summer. Carry it to a drain.
A straight wet stripA strip running up or across to a tap point is a pipe in its groove (chase). Tap the plaster along it: a hollow sound confirms it. Go to test 2.
Warm to the touchA patch that feels warm sits on the hot line from the geyser. Leave the geyser off for two days. If the patch shrinks, it is that line: plumber.
WC cistern runningPut a few drops of ink or food colour in the cistern and don't flush. Colour in the pan within 15 minutes means the cistern leaks inside. It also spoils the tank test, so fix it first.
Next door and the laneA neighbour's bathroom, a shared wall, or a lane drain running along your plinth can be the source. If your tests all come out clean, look over the wall.

Water near a switchboard, a fan point or a light? Switch off that MCB, or the main, before you touch anything or start any test.

The six tests

Run them in order. Each one rules a source in or out

You need a pencil, a phone camera, a stick, some kitchen foil, tape and a hose or buckets. Write down the date and the result of each test. If you send us photos, send that list too.

1 Jul3 Jul5 Jul Rain on 2 and 4 Jul:the line moved out= outside water
1Rain or all year

Date the edge of the patch

Finds: rain water vs pipe or ground
  1. Draw round the wet edge in pencil and write the date beside it. Take a photo from the same spot.
  2. Do it again every two or three days, through at least one spell of rain and one dry week.
Grows within a day of rain, shrinks after: outside water. Top-floor ceiling or the top of a wall: the roof, go to water dripping from the roof for the bucket test up there. Outside wall at any height: test 5.
Same or growing in dry weeks: a pipe, a bathroom or the ground. Tests 2, 3 and 4.
10 pm mark6 am level FELL All taps shut,pump off, cisternchecked: any fall= supply leak
2Supply pipe

Overnight tank test

Finds: a leak between the tank and the taps
  1. At bedtime shut every tap and the geyser inlet, and switch the pump off. Do the cistern check above first.
  2. Push a clean stick into the tank and mark the water line on it, or mark it on the tank wall with tape.
  3. At dawn, before anyone uses water, check the mark.
  4. If it fell, repeat for one night with only one bathroom's stop cock open at a time. The branch that makes it fall is the leaking one.
Level fell: a supply pipe or fitting leaks. plumber Show him the branch you found; he opens only that wall. Then fixing the joint.
Level held: the supply pipes are fine. A wet patch beside a bathroom is then the floor or the drain: test 3.
50 mm water, chalk the levelplug the trapridge atthe doorceiling below:check at 24 and 48 h A: trap plugged tests the floorB: trap open, buckets poured in, tests the trap
3Bathroom above or beside

Pond test, in two stages

Finds: the floor and its joints vs the trap and drain
  1. Stage A. Plug the floor trap tight (a polythene bag of sand works). Build a small ridge of mud or cement at the door sill. Fill the floor to about 50 mm and chalk the level. Don't use the bathroom.
  2. Check the ceiling below and the chalk line at 24 and 48 hours.
  3. Stage B, only if A stayed dry. Unplug the trap and pour bucket after bucket into it for 15–20 minutes. Check the ceiling below for the next hour.
A fails (ceiling wet or level drops): the floor or tile joints. applicator Bathroom water in the room below.
A passes, B fails: the trap or the drain pipe joint. plumber
Both pass, wet only when the shower or tap runs: a tap fitting or the wall joints behind it. Plumber first, then regrout.
2–3 ft OUTSIDEINSIDEground floortide line andwhite salt onboth facesfloor
4From the ground

Measure the height, check both faces

Finds: damp rising from the ground
  1. Measure from the floor to the top of the damp band at three places along the wall.
  2. Go outside and do the same on the other face of that wall.
  3. Look at what touches the wall outside: soil, a raised lane, an outside floor or a drain higher than your plinth.
Level band, about the same height along the wall and on both faces, up to 2–3 ft, white salt on the line, ground floor only: ground damp. applicator The fix, from the plinth up.
A patch that spreads from one spot, higher on one side: a pipe or drain low in the wall. Back to test 2.
123 below the sillwindow jointand chhajjaparapet bottom first, 15 min each
5Rain on the outside wall

Hose test, bottom up

Finds: the crack, joint or chhajja letting rain in
  1. Wait for two or three dry days so the patch inside has dried back to its pencil line.
  2. Spray the outside wall opposite the patch, starting at the bottom band, for about 15 minutes. Someone watches the patch inside.
  3. Nothing? Move up one band: the window frame joint and sill, then the chhajja, then the parapet top.
The patch darkens: the band you were spraying lets rain in. Mark the cracks there. applicator Waterproofing an outside wall.
Nothing after the parapet: it is not this wall. For the roof, use the bucket test on water dripping from the roof.
wallroomwallroom Wet on the room side= damp air (condensation)Wet behind the foil= water in the wall
6Damp air or water in the wall

Foil test

Finds: condensation vs real seepage
  1. Wipe the patch dry. Tape a 1 ft square of kitchen foil or thick polythene flat over it, taped on all four edges so no air gets behind.
  2. Leave it 24–48 hours, then peel it off and feel both sides.
Room side wet: moist room air condensing on a cool wall: closed rooms, almaris, monsoon nights. you Air the room, give it sun, keep furniture a few inches off the wall. Damp inside an almari.
Wall side wet: water is coming through the wall. Go back to tests 1 to 5.
Why the patch is often not under the sourceWater that gets into a slab runs along it before it drips, and water in a wall runs down and sideways before it shows. So a ceiling stain can be several feet from the crack above, and a damp patch next to a bathroom can come from the pipe on the far side of it. Test the nearest likely source first, then widen. The roof version of this, with a drawing: water dripping from the roof.
Read your results

What you found, who fixes it, and where to go next

The rule behind the table: water from a pipe is a plumber's job; water from rain, a floor or the ground is a waterproofing job. Calling the wrong one is how people pay twice.

What the tests showedWhere the water comes fromWho fixes itNext page
Grows after rain, top-floor ceiling or top of a wallRoof slab, outlet, or the joint where the parapet meets the roofapplicatorRoof leaking now · roof repair before the monsoon
Hose test brings the patch backCrack in outside plaster, window joint, chhajjaapplicatorOutside wall waterproofing
Tank level falls overnightSupply pipe or fitting inside a wall or floorplumberLeaking pipe joint · plumbers
Pond test A failsBathroom floor, tile joints, the floor-to-wall cornerapplicatorBathroom water in the room below · redoing a bathroom
Pond test A passes, B failsFloor trap or drain pipe jointplumberLeaking pipe joint
Wet only while a tap or shower runsTap fitting or the joints round itplumber, then regroutLeaking pipe joint
Level band up to 2–3 ft, both faces, saltGround water rising up a wall with no working damp-proof courseapplicatorSeelan from foundation to roof · plinth and DPC
Foil wet on the room sideDamp air condensingyouDamp in an almari
Under a tank overflow or AC drainPipe ending on the wallyou or plumberTurn the pipe to a drain

Not sure what the words mean (seelan, seepage, leakage, rising damp)? The four words and which page each one needs. Looking for someone to do the work: plumbers · waterproofing applicators.

Don't paint over the patch.Putty and paint on a wet wall come off by the next monsoon. Birla White says plainly that waterproof putty cannot repair plumbing leaks, roof leakage or active seepage.
Don't break tiles before tests 2 and 3.One night and two days tell you which wall or floor to open, and which not to.
Don't coat the roof for a pipe leak.If it drips on dry days, the roof is not the first suspect.
Don't judge on one dry week.Keep the dated pencil lines going until a spell of rain has come and gone.
Find yours

Answer five questions from your test results

The same order as the chart at the top. When you reach an answer, send it to us with a photo and we'll tell you what to buy for it.

Question 1 of 5
—

Most likely source

Answer the questions

Each answer rules one source in or out.

Send my answers on WhatsApp
Once you know the source

What each source needs from our shelf

Only after the test. Each product does one job, and the wrong one on the wrong source is money gone. Every one can be ordered from us.

After any repair, let the wall dry fully before putty: test by touch and colour, usually a few weeks after the leak is fixed. Then putty on a wall that had seelan. Today's prices: waterproofing rates.

Questions people ask us

Short answers

How do I find where water is leaking from in my wall? (pani kahan se aa raha hai)

Date the edge of the patch, then run the tests in order: does it follow rain, does the tank level fall overnight with every tap shut, does a bathroom pond test wet the ceiling below, is it a level band at the foot of a ground-floor wall, does a hose on the outside wall bring it back, and is a taped square of foil wet on the room side. Two or three of these usually point to one source.

Plumber or waterproofing applicator?

Water from a pipe under pressure, a tap fitting, a floor trap or a drain joint: plumber. Water from rain, a bathroom floor or the ground: waterproofing applicator. Run the tests first so you call the right one and pay once.

Can damp at the bottom of a wall be a pipe leak?

Yes, if a pipe or drain runs low in that wall. A pipe leak spreads from one spot and the tank test usually shows a fall. Ground damp is a level band along the whole wall, up to about 2–3 ft, at the same height inside and out, and never on an upper floor.

The plumber wants to break the tiles. Should I let him?

Not before the overnight tank test and the two-stage pond test. They tell you whether it is the supply pipe, the floor or the trap, so only that patch is opened. Dr. Fixit also notes that regrouting alone is unlikely to stop a leak that is already coming through, so know the source before paying for either.

How long do the tests take?

Tank test, one night. Pond test, one to two days. Foil test, one to two days. Hose test, an afternoon. Dating the patch needs a spell of rain and a dry spell, so start it today, even in winter.

Can there be rising damp on the first floor?

No. Damp from the ground climbs a ground-floor wall from below; UltraTech describes it as wet spots on the lower part of walls near the skirting. A wet patch upstairs comes from the roof, an outside wall, a bathroom or a pipe.

What about leak detection machines and thermal cameras?

Some specialists use moisture meters, listening devices and thermal cameras to find a hidden pipe leak without breaking much wall. They are useful once the tank test has proved there is a supply leak. They don't replace the six tests, which tell you whether there is a pipe leak at all.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. He wrote this page from the wet patches customers bring to our Reva Road store every monsoon, and checked each figure against the makers' sheets on 13 Nov 2026. Tests marked as usual practice are how site people here find leaks; no maker publishes them.

Where the facts come from

  1. UltraTech, How to prevent dampness in walls: rising damp by capillary action shows on the lower part of walls near the skirting; penetrating damp through cracks, frames and pipes; condensation from moist air on cold surfaces; damp-proof course about 150 mm above ground.
  2. Birla White, Seep Guard Seep Blocker 2K brochure: pressure-test plumbing before waterproofing; bathroom pond test with 50 mm of water for 48 h; plaster down to brick where salt shows.
  3. Birla White, Waterproof putty vs regular putty: waterproof putty cannot repair plumbing leaks, roof leakage or active seepage.
  4. UltraTech, Weather Pro waterproofing brochure: WP+200 at 200 ml per 50 kg bag; Hi-Flex in two coats, 14–15 sq ft per kg (read as per coat).
  5. Dr. Fixit, Waterproofing FAQs: regrouting alone is unlikely to stop an existing bathroom leak.
  6. Central Ground Water Board, Ground water information booklet, Muzaffarpur: water 0.67–5.21 m below ground after the monsoon (2011), which is why ground-floor damp is common here.
  7. Usual practice: dating the patch, the overnight tank test with branch-by-branch stop cocks, the two-stage pond test, the cistern colour check, the bottom-up hose test (about 15 minutes a band) and the taped foil test (24–48 h). The 2–3 ft height of ground damp is what we see in Muzaffarpur houses.

Send us a photo of the patch

One close up, one of the whole wall, and one of the floor or roof above it. Say when it gets worse. We'll tell you which test to start with.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR