Whole-house wiring kit: every coil, pipe, box, switch and MCB for a 1BHK, 2BHK or 3BHK, on one bill
7 MCBs + main, RCCB
7 MCBs + main, RCCB
9 MCBs + main, RCCB
Each kit is the complete material for wiring the house: V-Guard Classo+ wire in red, black and green, 20 and 25 mm conduit with couplers and bends, fan, round and metal switch boxes, V-Guard Torio switches, sockets, regulators and plates, V-Guard Elegna MCBs, a double-pole main, a 30 mA RCCB and the DB box. Every kit has one AC point, a geyser point and a pump line (3BHK: two of each AC and geyser).
Everything in each kit, by size and count
Wire, pipe and MCB counts are the same rows as our coil guide (10% spare included), so the two pages always agree. Boards and modules are counted from the boards drawn further down. Tap a line to see that product.
| Item | 1BHK2 rooms, kitchen, bath · 1 AC, 1 geyser, pump | 2BHK3 rooms, kitchen, 2 baths · 1 AC, 1 geyser, pump | 3BHK4 rooms, kitchen, 2 baths · 2 AC, 2 geysers, pump |
|---|---|---|---|
| Wire · V-Guard Classo+, 90 m coils, one red, one black, one green per set | |||
| 1.5 sq mmlights, fans, 6 A sockets | 3 coils1 set · ~281 m used | 6 coils2 sets · ~380 m | 6 coils2 sets · ~449 m |
| 2.5 sq mm16 A sockets, kitchen, AC, geyser, pump | 3 coils1 set · ~218 m | 3 coils1 set · ~238 m | 6 coils2 sets · ~323 m |
| 6 sq mm mainmeter to DB, cut length | about 33 m in every kit: 11 m each of red, black, green | ||
| Pipe and fittings · 3 m lengths | |||
| 20 mm conduitlight and fan runs | 30 | 41 | 49 |
| 25 mm conduitsockets, AC, geyser, pump, main | 28 | 31 | 40 |
| Couplersone per length | 58 | 72 | 89 |
| Bendsabout one per box | 18 | 24 | 30 |
| PVC taperolls | 4 | 6 | 8 |
| Boxes | |||
| Fan box with rodone per fan, into the slab | 2 | 3 | 4 |
| Round (circular) boxceiling junctions | 5 | 7 | 8 |
| Metal switch box8, 6 and 3 module | 8M ×26M ×3 · 3M ×6 | 8M ×36M ×4 · 3M ×7 | 8M ×46M ×5 · 3M ×9 |
| Switches and sockets · V-Guard Torio | |||
| 6 A one-way switchlights, fans, 6 A sockets | 18 | 25 | 30 |
| 16 A one-way switch16 A sockets, geyser, AC, pump | 8 | 9 | 12 |
| 6 A socket | 5 | 7 | 9 |
| 6/16 A combination socket | 7 | 8 | 10 |
| Fan regulator1 module | 2 | 3 | 4 |
| Indicatoron the geyser switch | 1 | 1 | 2 |
| Cover platesone per box, plus blank modules for spares | 117 blanks | 149 blanks | 1811 blanks |
| The board · V-Guard Elegna | |||
| MCBs, single pole | B10 ×2C16 ×4 | B10 ×2C16 ×4 | B10 ×2C16 ×5 |
| 16 A double-pole MCBone per geyser | 1 | 1 | 2 |
| Main, double pole20 or 25 A, by your sanctioned load | 1 | 1 | 1 |
| RCCB, 30 mA, double poleamps at or above the main | 1 | 1 | 1 |
| DB boxone way per MCB, main and RCCB 2 each | 16-way4 spare | 16-way4 spare | 16-way1 spare |
| Kit price today | Ask rate | Ask rate | Ask rate |
Not in the kit: labour; lights, ceiling and exhaust fans; the earthing electrode and its pit; the meter board (NBPDCL's); TV, data or USB modules. Each of these we can order for you; ask on WhatsApp for the time it takes. Earthing: the green wire to every point is in the kit, the same size as the phase (IS 732); the electrode is set for your soil, see earthing basics.
Why 1BHK and the coil guide's "2 rooms" match. A BHK counts bedrooms; the coil guide counts every room with a fan. A 1BHK has a bedroom and a hall, so it is the 2-room row there, and the 2BHK the 3-room row. The 3BHK is four rooms with two ACs and two geysers, worked out with the same lengths.
Ten kinds of board make up every kit
The switch and socket counts above are these boards added up. One module is one switch, regulator or indicator; a socket takes two. Each board keeps a spare module where it can, filled with a blank plate.
The same boards come ready-assembled, box, plate and modules, as switch-board sets. Adding just one room to an old house: one-room wiring kit.
The board in the 2BHK kit, way by way
Every MCB in the kit is matched to the wire behind it, never the other way round. 2.5 sq mm gets a 16 A MCB, never 20 A: V-Guard rates Classo+ 2.5 sq mm at 18 A inside a wall pipe. A 20 A MCB goes only on 4 sq mm. The earth wire is the same size as the phase beside it.
The geysers get double-pole 16 A MCBs, as CPWD's wiring specification recommends for water heaters: switched off, both phase and neutral are cut. That is why the DB counts two ways for each.
The main is double pole, 20 or 25 A by the sanctioned load on your NBPDCL bill; the 30 mA RCCB after it is the part that trips when current leaks through a person. Why each rating, and how to pick the main: which MCB for which load.
One kit, four deliveries, in the order the house needs them
You don't want switch plates lying on site through the dhalai. The kit is one list; we send each part when its stage comes, at that day's price, on the same bill book.
Before the slab
Fan boxes with rod, round boxes, the 20 mm pipe for ceiling runs (about half of it), couplers, bends, tape.
Before plaster
Metal switch boxes, the rest of the 20 mm and all the 25 mm pipe, the DB box.
Wire time
All coils, the 6 sq mm main, MCBs, the main switch and the RCCB.
After paint
Torio switches, sockets, regulators, indicators, plates and blanks.
What to check on site at each stage before it gets buried: new house wiring checklist. Pipes in the slab: conduit before slab casting. Delivery charge per trip: delivery and transport.
Three ways to get your list. Pick by how usual your house is.
1This kit
Fixed lists for the usual 1, 2 and 3BHK points. Quickest: say "2BHK kit" and get one price. Change a few lines below.
2The coil counter
Put in your own rooms, ACs and floors. Gives wire, pipe, boxes and MCBs, not switches. For two or three floors. Coil counter.
3Free estimate
Send the naksha; I count every point and send the whole list by stage, free, usually the same day. For odd shapes, shops below a house, or an electrician's point list. Wiring estimate service.
Need run lengths and voltage drop for a long line to a pump or a far room? The wiring calculator.
Add an AC or a geyser, and see the list change
Each extra AC or geyser gets its own line from the DB, its own board and its own MCB, so the list grows by more than one item. Choose here and send the list.
Most 1 and 1.5-ton splits sold here show 12 A or less on the plate. 12–16 A moves every AC to 4 sq mm wire and a 20 A C-curve MCB. Above 16 A, send us the plate photo.
Your kit list
Send me today's price on WhatsAppSame lengths and spare as the coil guide. Price: Ask rate, filled in with the day's rate on WhatsApp. Delivery per trip, separately.
What the kit is made of
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
V-Guard Classo+ wire1.5 and 2.5 sq mm on the shelf · 90 mAsk today's rateper coil 6 sq mm main wireMeter to DB · we order it for youAsk today's rateper metre UltraTech UltraBolt wireKit in this range instead, if you preferAsk today's rateper coilAny size, model or accessory not on the shelf, we order for you; ask on WhatsApp for the time it takes. Coil prices today: wire price list. All wire sizes: wires.
Short answers
What comes in a 2BHK wiring kit? (2BHK ki wiring ka poora saman)
Nine 90 m coils of V-Guard Classo+ (two sets of 1.5 sq mm, one of 2.5 sq mm), about 33 m of 6 sq mm main, 41 lengths of 20 mm and 31 of 25 mm conduit with couplers and bends, 3 fan boxes, 7 round boxes, 14 metal switch boxes with Torio plates, 25 six-amp and 9 sixteen-amp switches, 15 sockets, 3 regulators, an indicator, 7 MCBs, a DP main, a 30 mA RCCB and a 16-way DB.
Is the kit price fixed?
It is the day's price of every item on the list. Copper and switch prices move, so if you take the kit in stages, each delivery is billed at that day's rate. Ask on WhatsApp for today's figure.
Is delivery included?
No. Delivery is charged per trip, separately from the material, and you get the figure on WhatsApp before the vehicle leaves. Or collect from the store. See delivery and transport.
Does the kit include the electrician?
No, it is material only. Labour is between you and your electrician; house wiring should be done by an electrician licensed by the state.
Why a 16 A MCB on 2.5 sq mm when my electrician says 20 A?
V-Guard rates Classo+ 2.5 sq mm at 18 A inside a wall pipe, so the MCB has to sit below that. 20 A goes only on 4 sq mm (24 A in a pipe). Details on which MCB for which load.
My house has two floors. Which kit?
None of the three fits exactly: every floor up adds a climb to every run. Use the coil counter for wire and pipe, or send the naksha to the free wiring estimate for the full list.
Can I swap brands or change a module?
Yes. The wire can be UltraTech UltraBolt instead of Classo+, and any switch, socket, DB size or rating on the list can be changed or ordered. Tell us on WhatsApp which line.
Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur, and makes up these kits at the counter. Points per room and run lengths are usual practice for houses here; wire and MCB sizes follow V-Guard's own sheets.
Where the numbers come from
- V-Guard, Classo+ house wire: 90 m coils; current in conduit 1.5 sq mm 13 A, 2.5 sq mm 18 A, 4 sq mm 24 A.
- V-Guard, Elegna MCB: 10 kA, B and C curve, 6 to 63 A, single and double pole.
- V-Guard, Torio modular switches: 10-year warranty, dual-shutter sockets.
- IS 732 (standard figure): earth conductor the same size as the phase up to 16 sq mm.
- CPWD General Specifications for Electrical Works Part I (Internal) 2013: no socket for portable appliances inside a bathroom (cl. 3.11); double-pole protection recommended for water heaters (cl. 3.14).
- Points per room, board layouts, run lengths and 10% spare: usual practice, Tashya Ventures electrical counter, the same figures as our coil guide.
Say "2BHK kit" on WhatsApp
Or 1BHK, 3BHK, or your own room list. We send the kit with today's price on every line, and the delivery charge for your site.